Resolution No. 1444 RESOLUTION NO. 1 4 4 4
A RESOLUTION OF THE BOARD OF DIRECTORS OF SOUTH
TAHOE PUBLIC UTILITY DISTRICT CALLING FOR NOTICE TO
CONTRACTORS FOR SEALED PROPOSALS FOR CONSTRUCTION
OF FOREST SERVICE SEWER SYSTEM, STAGE 3
BE IT RESOLVED, by the Board of Directors of the SOUTH TAHOE PUBLIC
UTILITY DISTRICT, El Dorado County, California, as follows:
1. That the Board of Directors hereby calls for a Notice to Contractors
for sealed proposals for construction of Forest Service Sewer System, Stage 3,
consisting of furnishing and installing sewers in the sizes and approximate
quantities as follows:
4 -inch Sewer Pipe 9,300 linear feet
6 -inch Sewer Pipe 28,500 linear feet
8 -inch Sewer Pipe 6,000 linear feet
12 -inch Sewer Pipe 3,950 linear feet
Sewer Manholes 109 each
it Said Notice to Contractors to be in the form of Exhibit "A" attached hereto and made
a part hereof.
2. Said sealed proposals shall be received at the office of said District
in South Lake Tahoe, California, at the Treatment Plant thereof (Mailing address:
P.O. Box AU, South Lake Tahoe, California 95705), until 2 :00 P.M. on May 7,
1970, at which time all proposals shall be publicly opened, and will be referred to
and considered by the Board at its meeting at 8 :00 P.M. on said date.
* * * * * * * * * * **
PASSED AND ADOPTED at a regular meeting of the Board of Directors of the
SOUTH TAHOE PUBLIC UTILITY DISTRICT on the 2nd day of April, 1970 by the follow-
ing vote:
AYES: Directors Fesler, Kortes, Wakeman and Hegarty
NOES: None
ABSENT: Director Ream
ROBERT W. FESLER, President of the Board
South Tahoe Public Utility District
ATTEST:
DAVID W. CALLAHAN, Clerk and Ex-
Officio Secretary of the Board
South Tahoe Public Utility District
•
. .
. .
NOTICE TO CO'cZT.C2OP8
46, .
Co%lepesal will 1 2nc• at iTo ofac.e c the Eolfth Ti2,.h
Public Utility Ditric, leea.l. i_ t1'. .0:1 P. O. Lo.:
AU, South I.,:a. Tahoe, (7!„-21io.!!ia, 95705, u 2:00 p.m., May 7, 1970,
at v•hich tim•e thoy will b. plilicly o:?..(1 :tf.1 rea='L for costrrction
of South Tahoe PAlic Utility Di..L.rIct, Forest Service Sewes: System,
. Stage 3.
The work contemplated consists of the installation of sa,wers in the
sizes and approximate quantities as follows:
4-inch SsAler Pip 9,300 linear foot
6-inch Sewer Pipe 28,500 linear feet
8-inch Sower Pipe 6,000 linear feet
12-inch Sewer Pipe 3,950 linear feet
Sewer Manholes 109 each
In accordance with the provisions of Section 1770 of the Labor Code,
State of California, the South Tahoe Public Utility District has
ascertained the coral applicable prevailing wace rates to be as
shown in the Contract Docuants.
Contract Documents, including Plans and Specifications, may be
obtained at the office of Clair A. Hill & Associates, 1525 Court
Streot, P.O. Box 2088, Redding, California, upon payment, non-
refundable of $15.00 per s Contract Documents are available for
416, examination at the samo office.
.., .
No proposal will be accepted from a contractor who has not been •
licensed in accordance with tiro provisions of Chapter 791, Statutes
of 1929, as amonded, or Chapter 37, Statutes of 1939, as amended,
State of California. The South Taheo Public Utility District reserves
the right to reject any or all proposals.
•
Date: April 3, 1970
/s/ Davkl. W. Cal 1E11=
ffiara . .
Clerk and ex-officio Secretary,
• South Tahoe Public Utility District
•
•
(111, . •
, . .
• . ..
. .•
•
•
kre .
•
I hereby certify that the foregoing is a full, true and correct
copy of a. resolution duly and regularly adopted by the Board of Directors
of the South Tahoe Public Utility District, El Dorado County, California,
at a meeting thereof duly held on the 2nd day of April 1970, by the following
vote:
AYES, and in favor thereof, Directors: Fesler
Wakeman
Kortes
Hegarty
NOES, Directors: None
ABSENT, Directors: Ream
David W. Callahan, Clerk and Ex- Officio
Secretary, SOUTH TAHOE PUBLIC UTILITY DISTRICT
•