AP 02-04-10 °OTw ra o ,
ith NZ$'. r •1950 e4 �
C 0g " unity
SOUTH TAHOE PUBLIC UTILITY DISTRICT
REGULAR BOARD MEETING AGENDA
Thursday, February 4, 2010
2:00 P.M.
District Board Room
1275 Meadow Crest Drive, South Lake Tahoe, California
Richard Solbri•, General Mana•er Paul Sciuto, Assistant General Mana•er
Dale Rise, President BOARD MEMBERS Mary Lou Mosbacher, Vice President
James R. Jones, Director Eric W. Schafer, Director Chris Cefalu, Director
1. CALL TO ORDER REGULAR MEETING — PLEDGE OF ALLEGIANCE
2. COMMENTS FROM THE AUDIENCE (This is an opportunity for members of the public to address the
Board on short non - agenda items that are within the subject matter jurisdiction of the District. Five - minute
limit. No action can be taken on matters not listed on the agenda.)
3. CORRECTIONS TO THE AGENDA OR CONSENT CALENDAR
4. ADOPTION OF CONSENT CALENDAR (Any item can be removed to be discussed and considered
separately upon request. Comments and questions from members of the public, staff or Board can be taken
when the comment does not necessitate separate action.)
5. CONSENT ITEMS BROUGHT FORWARD FOR SEPARATE DISCUSSION / ACTION
6. ITEMS FOR BOARD ACTION REQUESTED BOARD ACTION
a. Ordinance No. 520 -10: Time Limits on Enact Ordinance No. 520 -10
Pg. 29 Sewer Permits Amending Section 4.2.10 and
(Tim Bledsoe) Adding Section 4.5.13 to the
Administrative Code Regarding
Time Limits on Sewer Permits
b. Headworks Replacement Project — Phase 1 Authorize Staff to Reject all Bids,
Pg. 35 (Julie Ryan) Modify Bid Documents, and Rebid
the Project
c. Payment of Claims Approve Payment (Payment of Claims
Pg. 39 will be distributed prior to, and at the Board
meeting)
REGULAR BOARD MEETING AGENDA — FEBRUARY 4, 2010 PAGE — 2
7. BOARD MEMBER STANDING COMMITTEE REPORTS
(Discussions may take place; however, no action will be taken)
a. Water & Wastewater Operations Committee (Jones / Rise)
b. Finance Committee (Schafer / Cefalu)
c. Executive Committee (Rise / Mosbacher)
d. Planning Committee (Mosbacher / Schafer)
8. BOARD MEMBER AD HOC COMMITTEE REPORTS
(Discussions may take place; however, no action will be taken)
a. Management/Union Medical Plan Negotiations Ad Hoc Committee (Schafer / Cefalu)
9. EL DORADO COUNTY WATER AGENCY PURVEYOR REPRESENTATIVES REPORT
10. BOARD MEMBER REPORTS (Discussions may take place; however, no action will be taken)
11. GENERAL MANAGER REPORTS (Discussions may take place; however, no action will be taken)
a. Integrated Regional Water Management Plan & Proposition 84
b. City Redevelopment Agency Presentation
12. STAFF / ATTORNEY REPORTS (Discussions may take place; however, no action will be taken)
a. Legislative Report (Dennis Cocking)
13. NOTICE OF PAST AND FUTURE MEETINGS / EVENTS
Past Meetings / Events
01/27/10 — ECC (Employee Communications Committee) Meeting
02/01/10 — Water and Wastewater Operations Committee Meeting
02/02/10 — Management/Union Medical Plan Negotiations Ad Hoc Committee Meeting
Future Meetings / Events
02/09/10 & 02/10/10 — Finance Committee Budget Meetings at District
02/10/10 — 9:00 a.m. — El Dorado County Water Agency Meeting in Shingle Springs
02/12/10 — Holiday — District Office Closed
02/15/10 — Holiday — District Office Closed
02/16/10 — 9:00 a.m. — Alpine County Supervisors Regular Meeting in Markleeville
02/16/10 — 3:30 p.m. — Water and Wastewater Operations Committee Meeting at District
02/18/10 — 2:00 p.m. — STPUD Regular Board Meeting at District
02/22/10 — 02/24/10 — ACWA Conference in Washington D.C.
02/22/10 — 02/24/10 — Utility Management Conference in San Francisco
02/24/10 — 8:00 a.m. — ECC (Employee Communication Committee) Meeting at District
(Director Cefalu is Board representative)
02/25/10 — 8:30 a.m. — Management/Union Medical Plan Negotiations Ad Hoc Committee
Meeting at District
14. CLOSED SESSION (Closed Sessions are not open to the public)
a. Pursuant to Government Code Section 54956.9(a) /Conference with Legal Counsel -
Pg. 41 Anticipated Litigation (One Case)
REGULAR BOARD MEETING AGENDA — FEBRUARY 4, 2010 PAGE — 3
b. Pursuant to Government Code Section 54956.9(a) /Conference with Legal Counsel —
Pg. 43 Existing Litigation re: Meyers Landfill Site: United States of America vs. El Dorado
County and City of South Lake Tahoe and Third Party Defendants, Civil Action
No. S -01 -1520 LKK GGH, United States District Court for the Eastern District of CA
15. ACTION / REPORT ON ITEMS DISCUSSED DURING CLOSED SESSION
16. ADJOURNMENT (To the next regular meeting, February 18, 2010, 2:00 p.m.)
The South Tahoe Public Utility District Board of Directors regularly meets the first and third Thursday of each month.
A complete agenda packet, including all backup information is available for review at the meeting and at the District
office during the hours of 8:00 a.m. — 5:00 p.m., Monday through Friday. A recording of the meeting is retained for 30
days after minutes of the meeting have been approved. Items on this agenda are numbered for identification purposes
only and will not necessarily be considered in the order in which they appear on the agenda. Designated times are for
particular items only. Public Hearings will not be called to order prior to the time specified, but may occur slightly later
than the specified time.
Public participation is encouraged. Public comments on items appearing on the agenda will be taken at the same time
the agenda items are heard; comments should be brief and directed to the specifics of the item being considered.
Comments on items not on the agenda can be heard during "Comments from the Audience;" however, action cannot
be taken on items not on the agenda.
Please provide the Clerk of the Board with a copy of all written material presented at the meeting. Backup to any
agenda item(s) not included with the Board packet will be made available when finalized at the District office, at the
Board meeting, and upon request to the Clerk of the Board.
The meeting location is accessible to people with disabilities. Every reasonable effort will be made to accommodate
participation of the disabled in all of the District's public meetings. If particular accommodations for the disabled are
needed (i.e., disability - related aids, or other services), please contact the Clerk of the Board at 530.544.6474,
extension 6203, at least 24 hours in advance of the meeting.
50tTH. 1r4110
ier •1950•**,,,,,
Ic �UT"Y �
CONSENT CALENDAR
FEBRUARY 4, 2010
ITEMS REQUESTED ACTION
a. North Apache Booster Station Authorize Task Order to Haen
Pg. 1 (John Thiel) Engineering for Structural Engineer-
ing Services, in the Amount Not to
Exceed $3,500
Authorize Task Order to AECOM for
b. North Apache Booster Station Electrical, Instrumentation and
Pg. 5 (John Thiel) Engineering Services, in the
Amount Not to Exceed $70,000
c. Arrowhead Well No. 3 Arsenic Treatment Facility Approve Change Order No. 4 to
Pg. 15 (Paul Sciuto) KG Walters, in the Amount of
$10,737.97; (2) Approve the Project
Closeout Agreement and Release of
Claims; and (3) Authorize Staff to
File a Notice of Completion with the
El Dorado County Clerk
d. Regular Board Meeting Minutes: Approve Minutes
Pg. 25 January 21, 2010
(Kathy Sharp)
South Tahoe Public Utility District • 1274 Meadow Crest Drive • South Lake Tahoe, CA 96150
Phone 530.544.6474 • Facsimile 530.541.0614 • www.stpud.us
General Manager
Richard H. Solbrig
Directors
r. 1
S o Chris Cefalu
James R. Jones
{ a, �•-i -= a �} t �"`; District "�' Mary Lou Mosbacher
Fu I l�G UtiIity Dist ric 4+� Dale Rise
Eric Schafer
1275 Meadow Crest Prive • South Lake Tahoe • CA 96150
Pitons 550 544-6474 • Fax 530 541 -0614
BOARD AGENDA ITEM 4a
TO: Board of Directors
FROM: John Thiel, Principal Engineer
MEETING DATE: February 4, 2010
ITEM — PROJECT NAME: North Apache Booster Station
REQUESTED BOARD ACTION: Authorize Task Order to Haen Engineering for
structural engineering services, in the amount not to exceed $3,500.
DISCUSSION: The District is designing a new booster station, North Apache Booster,
to replace the existing Apache Booster Station as the primary water service to the
Iroquois and Country Club zones. The existing Apache Booster Station is located in a
small building near the intersection of Apache Avenue and Ottawa Drive and boosts
water from the Arrowhead Zone to approximately 3,000 connections in the Iroquois and
Country Club zones. This station is approaching 50 years old, is undersized, and is
difficult to maintain. The station has low reliability because all three pumps are used (no
lag pump) during high demand periods, and there is no standby power system. The
District's pump crew has identified the replacement of this station as a top priority water
improvement project.
The new station will be constructed at 1922 Apache Ave. on a lot recently purchased by
the District and will include booster pumps and a diesel - powered standby generator.
Design, permitting, and the development of plans and specifications will be completed
by our Engineering Department with consultant assistance in the structural, electrical,
instrumentation and control disciplines. The attached proposal from Haen Engineering
describes the work and schedule for structural engineering support services.
This project is being grant funded by Fire Protection Partnership Funding - -USFS Forest
Health Funds and are subject to the ARRA requirements of Buy American, DBE, Davis
Bacon.
SCHEDULE: Complete plans by 3/22/10; Award Bid 5/20/10. NTP 6/03/10.
COSTS: Not to Exceed $3,500
ACCOUNT NO: 2029 - 8967 /IQBSTR
BUDGETED AMOUNT REMAINING: $464,041 2009/10; $1,300,000 2010/11
ATTACHMENTS: Proposals from Haen Engineering
-1-
John Thiel
February 4, 2010
Page 2
CONCURRENCE WITH REQUESTED ACT Ohl: CATEGORY: Water
GENERAL MANAGER: YES r NO
CHIEF FINANCIAL OFFICER: YES i / NO
-2-
Proposal of Professional Services
for
South Tahoe Public Utility District's
North Apache Booster Station
By Haen Engineering 1/26/10
Scope of Work: Provide structural engineering design, calculations and details
for a concrete masonry structure with pre - manufactured trusses and concrete
slab on grade foundation. Engineering of trusses to be provided by others.
Structural engineering shall include analysis for: vertical snow and dead Toads,
lateral wind loads and lateral seismic loads. The work product will be in
compliance with 2007 California Building Code and sufficient to obtain a
building permit from the El Dorado County Building Department. Services
include responding to plan corrections, if any, requested by the building
department. The work will be completed within three weeks of receiving a
notice to proceed or executed contract. During construction I will review shop
drawings and respond to design questions within one working day of request.
Fee Proposal: A lump sum of $1,100 is proposed for the structural design,
calculations and details. Response to shop drawing review, design questions,
and related work will be bitted at a rate of $120 /tour.
-3-
General Manager
Richard H. Solbrig
i
Directors
''" �� y � ``� Chris Cefalu
' J ames R. Jones
>R' '.;.'a ' -; "= .+ - " -` K � � [ • f'�"� UtiUty � '�" (• f �""� ise MaLou M her u1I e Pis ricV Eric Schafer
1275 Meadow Crest Drive • South Lake Tahoe • CA 96150
Phone 550 544 -6474 • Fax 530 541 -0614
BOARD AGENDA ITEM 4b
TO: Board of Directors
FROM: John Thiel, Principal Engineer
MEETING DATE: February 4, 2010
ITEM — PROJECT NAME: North Apache Booster Station
REQUESTED BOARD ACTION: Authorize Task Order to AECOM for electrical,
instrumentation and control engineering services, in the amount not to exceed $70,000.
DISCUSSION: The District is designing a new booster station, North Apache Booster,
to replace the existing Apache Booster Station as the primary water service to the
Iroquois and Country Club zones. The existing Apache Booster Station is located in a
small building near the intersection of Apache Avenue and Ottawa Drive and boosts
water from the Arrowhead Zone to approximately 3,000 connections in the Iroquois and
Country Club zones. This station is approaching 50 years old, is undersized, and is
difficult to maintain. The station has low reliability because all three pumps are used (no
lag pump) during high demand periods, and there is no standby power system. The
District's pump crew has identified the replacement of this station as a top priority water
improvement project.
The new station will be constructed at 1922 Apache Ave. on a lot recently purchased by
the District and will include booster pumps and a diesel - powered standby generator.
Design, permitting, and the development of plans and specifications will be completed
by our Engineering Department with consultant assistance in the structural, electrical,
instrumentation and control disciplines. The attached proposal from AECOM describes
the work and schedule for electrical, instrumentation and control engineering services.
This project is being grant funded by Fire Protection Partnership Funding - -USFS Forest
Health Funds and are subject to the ARRA requirements of Buy American, DBE, Davis
Bacon.
SCHEDULE: Complete plans by 3/22/10; Award Bid 5/20/10. NTP 6/03/10.
COSTS: Not to Exceed $70,000
ACCOUNT NO: 2029 - 8967 /IQBSTR
BUDGETED AMOUNT REMAINING: $464,041 2009/10; $1,300,000 2010/11
ATTACHMENTS: Proposals from AECOM
-5-
John Thiel
February 4, 2010
Page 2
CONCURRENCE WITH REQUESTED ACTION: CATEGORY: Water
r i
GENERAL MANAGER: YES Jed', _ _ NO
CHIEF FINANCIAL OFFICER: YES d litt NO
-6--
I AECOM
STPUD Apache Pump Station
Scope of Work
A. Design Project Oversight
1. Kevin Berryhili, PE will serve as AECOM's Project Manager with the authority and
responsibility to make project decisions, and monitor the progress of the work.
2. Pars Topjian, PE will serve as Electrical Engineer.
3. Gerardo Yniguez, PE will serve as Instrumentation Engineer.
4. Allen Randall, PE and Maris Janson, PE will serve as Electrical and Instrumentation
Quality Control Officers for the Electrical and Instrumentation disciplines respectively.
B. Project Coordination
1. Coordinate with the District.
2. Coordinate with Electric Utility Company.
3. Coordination will not require travel for AECOM's Engineers.
C. Project Design
1. Provide preliminary and final design services acceptable to the District for the Electrical
and Instrumentation disciplines. Drafting will be performed by AECOM's Cad
operators. Design of all other disciplines will be handled by the District.
2. Furnish the District with drawings, specifications, and opinion of probable construction
cost at 50% and 90 %, for District's review, and final for incorporation in the bid
documents.
3. (Not used).
4. Furnish the District with digital copies of the final project plans (AUTOCAD 2007 format)
and specifications (MS Word format) via email. Final plans will be signed by, and
stamped with, AECOM's signature and seal. Hard copies for such signature will be
provided by the District.
AECOM Water 1
-7-
Scope of Work AECOM
5. The District will prepare construction bidding contract documented including, Notice to
Contractors, General and Special Provisions, bid sheet, and technical specifications for
all other disciplines.
6. The District will prepare the design of the mechanical portion of the standby generator
system, including engine specifications, fuel, and ventilation systems. AECOM will
provide the District with a copy of their Generator Master Specifications for District's
edits of the mechanical portion.
7. AECOM anticipates the final design package for the Electrical and Instrumentation
disciplines to include approximately 9 sheets. A preliminary list of drawings are as
follows:
a) Instrumentation Legend and Symbols
b) Communication Block Diagrams
c) P &ID's
d) Instrument Details
e) Electrical Legend and Symbols
f) Single Line Diagrams
g) Electrical Site, Power and Control Plans
h) Conduit Schedules and Misc Details
0 Control Schematics
D. Electrical System Requirements
1. Per our understanding, the general function of the North Apache Pump Station is to
transfer water from a lower elevation distribution zone to a distribution zone at a higher
elevation. The higher elevation distribution zone contains two water tanks whose level
will dictate the control of the pump station.
2. The electrical system will comprise of a service switchboard, a motor control center
consisting of variable frequency drives, a standby generator, a transfer switch, the
electrical distribution to various pieces of equipment including three pump motors,
lighting, and a fire alarm system.
3. The generator will have a 200 gallon base mounted fuel tank. No additional bulk fuel
storage tank will be required.
4. This scope does not cover a fire suppression system, and interfacing with such a
system.
5. Security system will comprise of an intrusion limit switch at the door, communicating
with the SCADA system.
6. A requirement for an arc -flash hazard analysis to be performed by the Contractor, to
meet latest NFPA requirements will be included.
7. AECOM's scope of the standby system is limited to the electrical portion only. The
District will handle the mechanical aspects (Exhaust, Ventilation, Fuel, Engine).
AECOM Water 2
—8—
Scope of Work
I AECOM
AECOM will provide a standard specification section, with electrical portion edited, for
the District to handle editing of the mechanical portion.
8. The District will not furnish any of the major electrical equipment, including the service
switchboard, motor control center, transfer switch, and generator. l&C equipment to be
furnished by the District is covered under Section E of this proposal.
9. The utility meter is desired to be mounted inside, as part of the service switchboard.,
unless serving utility will object to it
10. No bypass starters will be required for the VFDs
11. One of the three pumps is standby. However service shall be sized to allow operation
of the three pumps.
12. The pumps are not considered fire pumps that are governed by NFPA 20.
E. Instrumentation and Controls (I &C) and Telemetry System
Requirements
1. Per our understanding, the general function of the North Apache Pump Station is to
transfer water from a lower elevation distribution zone to a distribution zone at a higher
elevation. The higher elevation distribution zone contains two water tanks whose level
will dictate the control of the pump station.
2. AECOM recognizes the District utilizes Motorola radio based Remoter Telemetry Units
(RTUs) and Wonderware InTouch SCADA HMI software packages for its SCADA
system. The RTUs are used to transmit data between the station and the District's
existing SCADA HMI. The SCADA HMI is used to control and monitor the Districts well,
pump station, and treatment plant facilities from the Districts central office. It is our
understanding the District prefers to take a District furnished contractor install
approach for the SCADA elements of the project. The District will purchase and furnish
to the contractor to install all of the components associated with the RTU Panel. The
District will directly hire the system integrator that presently does the District's existing
programming and will connect all of the field wiring installed in the panel by the
contractor.
3. The District staff will also make the necessary programming changes associated with
the central HMI SCADA software package. Thus, saving the cost associated with the
contractors mark -up for the project telemetry component. AECOM feels this is an
excellent approach for the District to follow.
4. AECOM will closely coordinate the project requirements with the Districts designated
system integrator.
5. AECOM will base the l &C design around the following features:
a) Automation will be PLC based. PLC will monitor and control the pumps. The PLC
will also interface with an RTU via hardwire signals.
AECOM Water 3
—9—
Scope of Work AECOM
b) An Operator Interface Terminal OIT will be specified to allow District to locally
monitor and control the pump station parameters.
c) There will be no water quality monitoring or chemical injection.
d) Pump station will be controlled to maintain a tank level. Level signal will be
received via RTU. No efforts are required from AECOM in generating the level
signal.
e) A maximum of two pumps may be operated concurrently.
f) Building intrusion and fire detection signals will be monitored and transmitted to
the RTU.
g) Radio survey, RTU programming, and SCADA modification efforts will not be
required from AECOM. This work will be provided by the District.
h) The antenna mast will be a conduit mounted on the station building. Antenna mast
will not require a freestanding tower or pole. District will provide AECOM with the
required antenna height.
i) Monitor the standby generator system.
j) Specified equipment will meet American Recovery And Reinvestment Act (ARRA)
requirements.
6. The following process parameters will be monitored by the PLC and transmitted to the
RTU:
a) Suction Pressure
b) Discharge Pressure
c) Discharge Flow
7. AECOM will assist District in specifying flowmeter and surge tank by providing
electrical and control requirements.
8. AECOM will prepare Process and Instrumentation Diagram (P &ID) drawings showing
the control requirements for the North Apache Booster Pump Station.
9. AECOM will prepare instrument, antenna and panel mounting detail drawings.
10. AECOM will prepare written control loop description describing the control strategy as
furnished to AECOM by the District staff.
11. The above approach will provide the District the necessary documentation for the
District furnished Telemeter/ and SCADA system components.
F. In -House Quality Control
1. AECOM will perform an in -house Quality Control review for the Electrical and
Instrumentation Disciplines. AECOM can provide Engineering Peer Review of
Disciplines that are the District's responsibility. An estimate for Peer Review services is
provided under a separate task titled OPTIONAL SERVICES.
AECOM Water 4
—10—
Scope of Work
AECOM
G. Information to be Provided by the District
1. Cad drawings of other disciplines to be used as base plans. Drawings wilt be Autocad
2007.
2. Process information to assist AECOM Instrumentation Engineer in preparing the control
loop descriptions.
3. Process information to assist AECOM Electrical Engineer to prepare control schematic
diagrams.
H. Schedule and Cost Estimates
1. Design will be completed by first week of March 2010.
2. Construction will be completed no later than March 2011.
3. AECOM will provide opinions of construction cost of the electrical and instrumentation
disciplines at 50%, 90 %, and 100% completion.
Bidding Phase
1. Answer RFI's from prospective bidders
2. Produce addenda as needed.
J. Assumptions
This scope of services is based upon certain assumptions regarding the characteristics of the final
project. These assumptions will be investigated during preliminary design, and appropriate adjustments
to scope and fee will be made, if necessary:
1. Design of a brand new pump station.
2. Basic elements include three pumps in the order of 60 HP each, to be controlled by
VFDs..
3. A standby generator to provide power in case of utility power failure.
4. No assistance by AECOM for permits is anticipated.
5. Arc -Flash Hazard Analysis will be required to be provided by the Contractor.
K. Construction Phase Services
1. AECOM will review and respond to contractor electrical and t &C questions.
AECOM Water 5
-11-
•
{
Scope of Work
I AECOM
2. AECOM will review electrical and I &C Shop Drawings.
3. Site Visits:
a) AECOM will attend the electrical and I &C system start-up for the Booster Pump
Station.
b) AECOM will review the electrical and I &C installation to be in accordance with the
plans & specifications and generate punchlist items.
c) Only one site visit (per discipline) will be budgeted for the above two tasks.
Additional budget will be required if more than one site visit is needed.
AECOM Water 6
-12-
Scope of Work I AECOM
AECOM Provisions
,..t Deleted: <sp>
,Right to Rely
Consistent with the professional standard of care and unless specifically provided herein, AECOM will
be entitled to rely upon the accuracy of data and information provided by the District or others without
independent review or evaluation.
Opinions of Cost
Any Estimate of the project's Probable Construction Cost prepared by AECOM is an opinion
representing AECOM's judgment as a design professional. Estimates of Probable Construction Cost
are supplied for the general guidance of CLIENT. Since AECOM has no control over the cost of labor
and material, or over competitive bidding or market conditions, AECOM does not guarantee the
accuracy of such estimates as compared to AECOM bids or actual cost to the District.
Contractor Indemnification/Insurance •
CLIENT will include in the general conditions of any construction contract, language which states that
the construction contractor is required to hold harmless and defend the District, AECOM, and their
agents, employees and consultants, from all suits and actions, including attorneys' fees, and all costs of
litigation and judgments of any nature and description arising out of or incidental to the performance of
the construction contract or work performed thereunder. The District, AECOM, their agents, employees
and consultants shall also be named as additional insureds in any construction contractor's insurance
policies.
Reuse of Documents/CADD Data
Documents, drawings, specifications, and electronic information /data, including computer aided
drafting and design ("CADD "), prepared by AECOM pursuant to this agreement are not intended or
represented to be suitable for reuse by CLIENT or others on extensions of the Project or on any other
project. Any use of completed documents for other projects and any use of incomplete documents
without specific written authorization from AECOM will be at the District's sole risk and without liability to
AECOM. The District assumes full responsibility for such changes unless the District has given AECOM
prior notice and has received from AECOM written consent for such changes. Electronic data delivered
to the District will not include the professional stamp or signature of an engineer or architect. The District
agrees that AECOM shall not be liable for claims, liabilities or losses arising out of, or connected with
the decline of accuracy or readability of electronic data due to inappropriate storage conditions or
duration.
Delay
AECOM will not be responsible for delays due to causes beyond AECOM's reasonable control. In the
case of any such delay, the time of completion will be extended accordingly. In the event that AECOM's
services hereunder are delayed by the District or others for a period in excess of six (6) months,
AECOM's compensation shall be subject to renegotiation.
AECOM Water 7
— 13-
General Manager
Richard H. So'brig
∎:—" Directors
,�` �.►.L �" �`_..tt., o � T a � Chris Cefalu
`, ,, •,, James R. Jones
"':iii""'"— .. N. . Mary Lou Mosbacher
- x F ' uHic Utifity E2 Dale RISC
Eric Schafer
1275 Meadow Crest Drive • South Lake Tahoe • CA 96150
Phone 530 54+6474 • Fax 530 541-0614
614
BOARD AGENDA ITEM 4c
TO: Board of Directors
FROM: Paul A. Sciuto, Assistant General Manager
MEETING DATE: February 4, 2010
ITEM — PROJECT NAME: Arrowhead Well No. 3 Arsenic Treatment Facility
REQUESTED BOARD ACTION: (1) Approve Change Order No. 4 to KG Walters
(KGW), in the amount of $10,737.97; (2) Approve the Project Closeout Agreement and
Release of Claims; and (3) Authorize staff to file a Notice of Completion with the El
Dorado County Clerk.
DISCUSSION: The itemized parts of Change Order No. 4 are as follows:
Item 1, in the amount of $10,737.97, is for extra services to modify specification
sections in the contract documents to satisfy construction contract provisions required
under the Safe Drinking Water State Revolving Fund (SDWSRF) and the American
Recovery and Reinvestment Act (ARRA). In an attempt to secure grant funding for this
project, District staff had to negotiate ARRA grant conditions with KGW and the
California Department of Public Health (CDPH). The District requested that KGW
participate in these negotiations since the project was substantially completed prior to
receiving the contract provisions. The District has completed its work with KGW,
however CDPH did not accept any proposed changes and will not award grant funds for
this project.
Staff has performed a final inspection of the project and has found that as of
October 23, 2009, KG Walters Construction has met all contract requirements.
SCHEDULE: As soon as possible
COSTS: $10,737.97
ACCOUNT NO: 2029 - 8864 /ARSNIC
BUDGETED AMOUNT REMAINING: $355,107
ATTACHMENTS: Change Order No. 4, Closeout Agreement and Release of Claims,
Notice of Completion.
-15-
Paul Sciuto
February 4, 2010
Page 2
CONCURRENCE WITH REQUESTED nn ACTI • N: CATEGORY: Water /F�
GENERAL MANAGER: YES ti : / NO
CHIEF FINANCIAL OFFICER: YES NO
-16-
u T CHANGE ORDER NUMBER 4
Project: ARROWHEAD WELL NO. 3 ARSENIC TREATMENT
, FACILITY
14, 1150.w� A
(mull ow- Contractor KG Walters Construction, Inc.
Date 02.04.2010 PO # P21290
The Contract Shall Be Changed As Follows:
1) Additional time and costs expended by contractor in an effort to provide
documentation of compliance with state and federal grant funding agencies'
requirements. District and contractors proposed to append Volume 1 of the
Contract Documents (December 2008) to include Section 00 74 00 Grant
Conditions and Section 00 75 00 Grant Forms. These forms were required by
the Safe Drinking Water State Revolving Fund (SDWSRF) and the American
Recovery and Reinvestment Act (ARRA) in order for grant monies to be awarded
for the work done in this project. The State did not accept the proposed changes
so therefore there are no changes to the Contract Documents. See attached
invoices.
TOTAL FOR ITEM 1: $10,733.97
TOTAL FOR CHANGE ORDER NO. 4, ITEM 1 IS: $10,733.97
Original Contract $730,600.00 212 Calendar Days
Previous Change Order $29,378.46 21 Calendar Days
Current Contract $759,978.46 233 Calendar Days
THIS CHANGE ORDER $10,733.97
New Contract Total $770,712.43
Contractor agrees to make the herein - described changes in accordance with the terms hereof. The
change in contract price and /or contract time noted Is full settlement for costs incurred because of the
change(s) described, unless specifically noted In individual description(s).
Date:
Authorized By STPUD Board President
Date:
Accepted By Contractor
Date:
Reviewed By
-17-
CLOSEOUT AGREEMENT AND RELEASE OF CLAIMS
THIS AGREEMENT AND RELEASE OF CLAIMS is made in South Lake Tahoe, California, this
day of February 2010 by and between South Tahoe Public Utility DISTRICT, hereinafter
referred to as "DISTRICT ", and K.G. Walters Construction Co., Inc. hereinafter referred to as
"CONTRACTOR ".
KNOW ALL PERSONS BY THESE PRESENTS:
1. That the undersigned, as the authorized representative of CONTRACTOR, for and in
consideration of Seven Hundred Thirty Thousand Six Hundred Dollars ($730,600.00),
contract amount, and the sum of Forty Thousand One Hundred Twelve Dollars and Forty-
Three Cents ($40,112.43) for said Contract Change Orders Nos. 1 through 4, receipt of
which is hereby acknowledged, does hereby and for each of its successors, assigns and
partners, release acquit and forever discharge the SOUTH TAHOE PUBLIC UTILITY
DISTRICT OF EL DORADO COUNTY, CALIFORNIA, and each of its successors, assigns,
officers, agents, servants, and employees, from any and all rights, claims, demands, debts,
obligations, liabilities, actions, damages, costs, expenses and other claims whatsoever,
which might have been asserted against DISTRICT by reason of any matter or thing which
was the subject matter of or basis for:
A. The performance of all terms and conditions of that certain agreement dated
February 27, 2009 for Purchase Order No. P21290, DISTRICT project described as
Arrowhead Well No. 3 Arsenic Treatment Facility project.
B. Change Orders Nos. 1 through 4 as approved by the parties, pertaining to Purchase
Order No. P21290 and shown in Payment Request No. 8, dated February 18, 2010.
2. That the undersigned, as the authorized representative of DISTRICT, for and in
consideration of the CONTRACTOR's completion of Purchase Order No. P21290 does
hereby and for each of its successors, and assigns, releases, acquits and forever discharge
K.G. WALTERS CONSTRUCTION CO., INC., and each of its successors, assigns, officers,
agents, servants, and employees, and sureties from any and all rights, claims, demands,
debts, obligations, liability, actions, costs, expenses whatsoever which might have been
asserted against CONTRACTOR, except for the rights accruing to the DISTRICT in
California Code of Civil Procedure Section 337.15, Entitled "Ten Years - Action to Recover
Damage from Latent Deficiencies in Planning or Construction of Improvements to Real
Property," which rights are specifically not released, and except for warranties and sureties
provided by reason of any matter or thing which was the subject matter of or basis for:
A. The performance of all terms and conditions of that certain agreement dated
February 27, 2009 for Purchase Order No. P21290, DISTRICT project described as
Arrowhead Well No. 3 Arsenic Treatment Facility project.
B. Change Orders Nos. 1 through 4 as approved by the parties, pertaining to Purchase
Order No. P21290 and shown in Payment Request No. 8 dated February 18, 2010.
3. Nothing contained herein shall waive or alter the rights, privileges, and powers of the
DISTRICT or the duties, liabilities and obligations of the CONTRACTOR and its surety in
respect to any portions of the Specifications for Purchase Order No. P21290.
4. The DISTRICT has received no claims from the CONTRACTOR.
-18- 1
5. The DISTRICT has received a stop notice from Associated Concrete Pumping
( "Associated "), . which asserts that Associated has not been paid by Gentry Masonry
Construction ( "Gentry"), for concrete pumping, material belting, rock and sand that
Associated claims it provided Gentry for use on the Arrowhead Well No. 3 Arsenic
Treatment Facility project. As described in its January 26, 2010 letter, in response to the
stop notice, the DISTRICT will withhold $4,881.83 in the event such amount becomes
payable to CONTRACTOR.
6. Upon execution of this agreement, the DISTRICT agrees to immediately file and record a
NOTICE OF COMPLETION with the County Recorder in order to begin the running of the
statutory lien period.
7.
The presently retained amount is $ 38,535.62
Original Contract amount $730,600.00
Total Change Order Amount $ 40,112.43
Less: Amount Previously Paid $721,979.54
(Request Nos. 1 through 8)
Retainage $ 38,535.62
BALANCE: $ -0-
The retainage, or that portion of it that is not subject to the DISTRICT's withholding in response to
a valid stop notice, will be released to the CONTRACTOR at the expiration of the lien period 35
(thirty -five) calendar days after date of recording a NOTICE OF COMPLETION by El Dorado
County Recorder or when all liens and stop notices have been released, whichever last occurs.
Release pursuant to this agreement shall not apply to CONTRACTOR's rights to the presently
retained amount until such time as such amounts are received in full by CONTRACTOR.
8. CONTRACTOR and DISTRICT agree that the total adjusted contract price and time of
performance for Purchase Order No. P 21290 after the execution of change orders, shall be
as follows:
Original Contract Price $730,600.00
Original Calendar Days 212
Total Adjusted Price $770,712.43
Total Adjusted Calendar Days 233
9. It is understood and agreed by the undersigned that the facts with respect to which the
foregoing Release is given may hereafter turn out to be other than or different from the facts
in that connection now known to be or believed by said undersigned to be true, and the
undersigned hereto expressly assume the risk of the facts turning out to be different than
they now so appear, and agree that the foregoing Release shall be, in all respects, effective
and not subject to termination or recession by any such difference in facts and undersigned
hereby expressly waive any and all rights the undersigned have or may have under
California Civil Code Section 1542, which provides as follows:
"A general release does not extend to claims which the creditor does not know or
suspect to exist in his favor at the time of executing the Release which if known by
him must have materially affected his settlement with the debtor."
-19- 2
i
10. The releases made by the CONTRACTOR and the DISTRICT herein are not to be
construed as an admission or admissions of liability on the part of either party and that the
parties deny liability hereof. The undersigned agree that they will forever refrain and
forebear from commencing, instituting or prosecuting any lawsuit, action, or other
proceeding against the other party based on, arising out of, or in any way connected with
the subject matter of this Release.
11. The CONTRACTOR hereby releases the DISTRICT from all claims, including those of its
Subcontractors for all delay and impact costs, if any.
12. The CONTRACTOR represents and warrants to the DISTRICT that the CONTRACTOR
has not heretofore assigned or transferred or purported to assign or transfer to any person,
firm, corporation, association or entity any of the rights, claims, warranties, demands, debts,
obligations, liabilities, actions, damages, costs, expenses and other claims whatsoever and
the CONTRACTOR agrees to indemnify and hold harmless the DISTRICT against, without
limitation, any and all rights, claims, warranties, demands, debts, obligations, liabilities,
actions, damages, costs, expenses and other claims, including attorney's fees, arising out
of or connected with any such assignment or transfer or purported assignment or transfer.
13. The undersigned acknowledge that they have been represented by counsel of their own
choice in connection with the preparation and execution of this Closeout Agreement and
Release of Claims. The undersigned acknowledge and represent that they understand and
voluntarily consent and agree to each and every provision contained herein.
14. The undersigned further declare and represent that no promise, inducement or agreement,
not herein expressed, have been made to the undersigned and that this Release contains
the entire agreement among the parties hereto and that the terms of the Release are
contractual and not a mere recital.
15. The persons executing this Closeout Agreement and Release of Claims represent and
warrant to the other party that the execution and performance of the terms of this Release
have been duly authorized by all requisite corporate, partnership, individual, or other entity
requirements and that said persons have the right, power, legal capacity and authority to
execute and enter in the Closeout Agreement and Release of Claims.
RICHARD SOLBRIG, GENERAL MANAGER DATED
ATTEST: KATHY SHARP, CLERK OF BOARD DATED
K.G. WALTERS CONSTRUCTION CO., INC.
By:
JOHN COLLINS, PROJECT MANAGER DATED
-20- 3
RECORDING REQUESTED BY:
South Tahoe Public Utility District
Attention: Heidi C. Baugh
WHEN RECORDED MAIL TO:
South Tahoe Public Utility District
1275 Meadow Crest Drive
South Lake Tahoe
CA 96150
SPACE ABOVE THIS LINE FOR RECORDER'S USE
APN: 034 - 294 -04 NOTICE OF COMPLETION
NOTICE IS HEREBY GIVEN THAT:
1. The undersigned is OWNER or agent of the OWNER of the interest or estate stated below in the property hereinafter described.
2. The FULL NAME of the OWNER is South Tahoe Public Utility District
3. The FULL ADDRESS of the OWNER is 1275 Meadow Crest Drive, South Lake Tahoe, CA 96150.
4. The NATURE OF THE INTEREST or ESTATE of the undersigned is: In fee.
(If other than fee, strike "in fee" and insert here, for example, "purchaser under contract of purchase," or "lessee."
5. The FULL NAMES and FULL ADDRESSES of ALL PERSONS, if any, WHO HOLD SUCH INTEREST or ESTATE with the undersigned as
JOINT TENANTS or as TENANTS IN COMMON are:
Name & Address
Name & Address
6. The FULL NAMES of FULL ADDRESSES OF THE PREDECESSORS in INTEREST of the undersigned if the property was transferred
subsequent to the commencement of the work of improvement herein referred to:
Name & Address
Name & Address
7. A work of improvement on the property hereinafter described was COMPLETED on 10/30/2009.
8. The work of improvement completed is described as follows: Arrowhead Wel 1 #3 Arsen i c Treatment Facility.
9. The NAME OF THE ORIGINAL CONTRACTOR, if any, for such work of improvement is K.G. Walters Construction Co., Inc.
10. The street address of said property is 1961 Arrowhead Avenue, unincorporated area of Meyers.
11. The property on which said work of improvement was completed is in the City of County of El Dorado, State of Califomia,
and is described as follows:
As shown in Exhibit "A" attached hereto and made a part hereof, and commonly known as
DATE: February 4, 2010 T p� y� N
AL ( KISL, boar resideont ER
VERIFICATION FOR INDMDUAL OWNER: South Tahoe Public Uti ll ity District
I, the undersigned, dedare under penalty of perjury under the laws of the State of California a that I am the owner of the a' oresai interest or estate in
the property desaibed in the above notice; that I have read said notice, that I know and understand the contents thereof, and the facts stated therein
are true and correct.
DATE AND PLACE SIGNATURE OF OWNER NAMED IN PARAGRAPH 2
VERIFICATION FOR NON- INDMDUAL OWNER: Snuth TahnP Pu i rJltiltty Ilj stri
I, the undersigned, dedare under penalty of perjury under the laws of the State of Califomia that I am the Board President
of the aforesaid interest or estate in the property described in the above notice; that I have read the said notice, that I know and understand the
contents thereof, and that the facts stated therein are true and correct.
2/4/2010 at Smith I akp Tahne, Califnrnia
D AND PLACE SIGNATURE OF PERSON SIGNING ON BEHALF OF OWNER
DALE RISE, Board President
South Tahoe Public Utility District
—21—
Notice of Completion
EXHIBIT "A"
Notice of Completion
Arrowhead Well No. 3 Arsenic Treatment Facility
The site of the work is located on DISTRICT property (APN 034 - 294 -04), within an
established residential neighborhood, at 1961 Arrowhead Avenue, in the unincorporated
area of Meyers, in the County of El Dorado, California.
The work completed consists of:
Construction of a single building and new site fencing; piping demolition and tree
removal; installation and connection of piping to and from the arsenic treatment facility;
and installation of pre - purchased arsenic treatment equipment within the building.
//I
//I
/1/
Notice of Completion
Arrowhead Well No. 3 Arsenic Treatment Facility
EXHIBIT "A"
-22--
ss Far A C
g_ 1 ..,� e South
e yi a :.
Public Utility y District
1275 Meadow Crest Drive • South Lake Tahoe • CA 96150 -7401
Phone 530 544-6474. Fax 530 541 -0614 • www.stpud.us
CERTIFICATION
I hereby certify that the foregoing is a full, true, and correct copy of the
Notice of Completion that was approved by the Board of Directors of the South
Tahoe Public Utility District, County of El Dorado, State of California, and
executed by Board President, Dale Rise.
Date Approved:
Certified by:
Kathy Sharp, Clerk of the Board
-23-
iSpV -H -- Ay0
`'Cr • 1950 • V
trnury
SOUTH TAHOE PUBLIC UTILITY DISTRI CT
A
Richard Solbri , General Mana er Paul Sciuto, Assistant ne Man er
Dale Rise, President BOARD MEMBERS Mary Lou Mosbaoher, President
James R. Jones, Director Eric W. Schafer, Director Chri CefaIu, Director
REGULAR MEETING OF THE BOARD OF DIRECTORf
SOUTH TAHOE PUBLIC UTILITY DISTRICT
JANUARY 21, 2010
MINUTES
The Board of Directors of the South Tahoe Public Utility District met in a regular session,
January 21, 2010, 2:00 P.M., District Office, 1276 Meadow Crest Drive, South Lake Tahoe,
California.
BOARD OF DIRECTORS: ROLL CALL
President Rise, Directors Cefalu, Jones, Schafer.
Director Mosbacher was absent.
STAFF:
Solbrig, Sharp, Sciuto, Hughes, COckingt Swain,
R. Johnson, Curtis, Brown.
Attorney Herrema participated -Via teleconference.
GUESTS:
Ernie Claudio
Eric Schafer led the pledge to the flag. PLEDGE OF ALLEGIANCE
Ernie Claudio reeiritid the Carpenters Union plans to COMMENTS FROM THE AUDIENCE
look into the le g" lity of requiring local agencies to
provide bidding discounts for local contractors, and
r . quire that out -of -town contractors hire a certain
p entae of local laborers.
Director Schafer received clarification regarding the CONSENT CALENDAR
County's impact on the timeline for the Angora and
Echo View Tank Replacement Project.
Moved Schafer / Second Cefalu/ Mosbacher Absent /
Passed to approve the Consent Calendar as submitted:
-25-
REGULAR BOARD MEETING MINUTES - JANUARY 21, 2010 PAGE - 2
a. Headworks Replacement Project: Phase 2 - CONSENT CALENDAR
Approved proposal from Carollo Engineers for (continued)
consulting services, in the amount not to exceed
$13,750;
b. Angora and Echo View Tank Replacements -
Authorized staff to advertise for bids for:
(1) Construction of the replacement tank and
site work at Angora Highlands; and (2) Construction
of the replacement tank, waterline, and site work
at Echo View Estates;
c. InfraMap Software Purchase - Authorized purchase
of six licenses of InfraMap software from iWater
Inc., for $2,399 each for a total of $14,395, plus
tax;
d. 2010 & 2011 Bulk Sodium Hypochlorite Supplies -
Awarded bid to the lowest responsive bidder, Sierra
Chemical Co., in the estimated amount of
$124,040.25;
e. El Dorado County Water Agency Board of Direr " tors -
(1) Appointed Director Jones to serve as pufyor
representative; (2) Appointed Director Riv to serve
as alternate; and (3) Adopted Resolution . 4$18 -10
supporting the appointments through Febrility t, 2014;
f. Final and Secondary Effluent P Station - Authorized
staff to release the security ' . Pacific Mechanical
Corporation;
g. Approved Regular Board Meeting Minutes:
January 7, 2010.
ITEMS FOR BOARD ACTION
Moved Schafer / Sepond Cefalu / Mosbacher Absent / PAYMENT OF CLAIMS
Passed to apPtove payment in the amount of
$910,230.08.
Water end Wastewater Operations Committee: The BOARD MEMBER STANDING
cdiomittie met January 19. Minutes of the meeting COMMITTEE REPORTS
are available upon request.
At the January 13 meeting there was some discussion EL DORADO COUNTY WATER
about reorganizing the structure and staffing of the AGENCY PURVEYOR
agency. An opinion from leg. counsel is pending regard- REPRESENTATIVE REPORT
ing the legality of the agency's practice of redirecting tax
monies and redistributing a portion of them back to the
purveyors in the form of grants.
-26-
REGULAR BOARD MEETING MINUTES - JANUARY 21, 2010 PAGE - 3
Director Schafer reported on his attendance at the BOARD MEMBER REPORTS
CASA Conference. Topics of discussion included
wellness and health care, climate change, and alter-
nate energy bills. He suggested the District look into
power generation (the District has a grant application
pending for a small scale project to generate power
for the C- line). He also suggested having an energy
audit performed on District facilities.
President Rise reported on two items:
1) He requested that Director Jones attend the
February 2 Board of Supervisors meeting along with
staff to hear the City's redevelopment presentation.
The Redevelopment Agency will also give a presen-
tation to the City Council on February 11, and at the
District Board meeting on February 18.
2) He requested that Board members submit written
requests for travel plans for the next budget year.
Richard Solbrig reported on two items: GENERAL MANAGER REPORTS
1) The period for legal challenges on the Diamond
Valley Ranch Master Plan EIR has past. The Board s
Planning Committee will be preparing for discusne
with Alpine County and the ranchers. Staff is consider-
ing future projects and uses for the property.
2) The radon monitoring required by the. TRP{ermit
for South Upper Truckee Well No. 3 showed no
significant change from pre-operatioortccoOstuoperation.
The project helped meet the stanJ r or.the lead
and copper rule. •
Chief Financial Officer: Paul Hughes reported 239 STAFF REPORTS
customers signed up for the new on -line bill pay
feature.
He received consensus fVein the Board to move ahead
with the ordinance to set tfrne lines on sewer permits
with the provisions that the life of the permit would
be three yearS7 anq at the end the customer could
reapply after Owing an administrative fee and ensuring
current code regulations are met on an annual basis
until, xhe customer's connection is completed.
3:00 P.M: ADJOUNMENT TO CLOSED
SESSION
-27-
REGULAR BOARD MEETING MINUTES - JANUARY 21, 2010 PAGE - 4
ACTION / REPORT ON ITEMS DISCUSSED DURING CLOSED SESSION
No reportable Board action. Pursuant to Government Code
Section 54956.9(a) /Conference
with Legal Counsel — Existing
Litigation re: Meyers Landfill Site:
United States of America vs,. El
Dorado County and Ci } of South
Lake Tahoe and Thir..arty
Defendants, Civil Actin rNo.
S -01 -1520 LKK G011, 1 *. District
Court for the Eastern,DIstrict of Ca.
Moved Jones / Second Schafer / Mosbacher Absent / Pursuant t a ent Code
Passed to approve settlement agreement resolving Section : 9( )/C onference
litigation regarding the stop notices on the 2008 Al with Ltgal Ccurtsel — Existing
Tahoe Waterline Replacement Project and the Tata/ Litigation.: Tahoe Asphalt, Inc., and
Granite Mountain Waterline Replacement Project, Tahoe Asphalt Materials Company,
disbursing the remaining funds retained on the projects, LL tts. STPUD, Case No.
and dismissing the District's cross complaint. SO420090104, El Dorado Superior
Court
3:15 P.M. ADJOURNMENT
Dale Rise, Board President
South Tahoe Public Utility District
ATTEST:
Ka hy Clerk of the Board
South Tahoe Public Utility District
-28-
General Manager
Richard H. 5olbrig
Directors
out � +► Chris Cefalu
f h ,, • w .. 5 James R. Jones
+c r.• • r • • M ary L M osbacer
Pu I c Uti l ity Citric h
osbac er
Eric Schafer
1275 Meadow Crest Prive • South Lake Tahoe • CA 86150
Phone 530 544 -64F� 74 • Fax 530 541 -0614
BOARD AGENDA ITEM 6a
TO: Board of Directors
FROM: Tim Bledsoe, Manager of Customer Service
MEETING DATE: February 4, 2010
ITEM — PROJECT NAME: Ordinance No. 520 -10: Time Limits on Sewer Permits
REQUESTED BOARD ACTION: Enact Ordinance No. 520 -10 Amending Section
4.2.10 of the Administrative Code Regarding Time Limits on Sewer Permits.
DISCUSSION: Currently, the Administrative Code does not have a time limit or
expiration date for sewer permits. As a result, there are many outstanding permits in
which connections to the sewer system have not been made. This has caused some
confusion for those property owners holding outstanding permits as to which of the
District's Ordinances, rules and regulations apply. The proposed amendment states that
if the permit holder does not construct the sewer connection by the end of three years,
they can apply for a year to year extension providing the administrative fee of $150.00 is
paid. If the administrative fee is not paid, the permit will be placed into a suspended
status and no connection to the District's sewer system shall be made until all
administrative fees for each year extended has been paid. At any time the permit holder
can terminate its sewer connection permit and the District shall refund the sewer
connection fee to the permit holder pursuant to Administrative Code section 4.5, paid by
the permit holder upon receipt of its permit. Upon termination the permit holder will not
be refunded any administrative fees paid for extensions of the permit term. A sewer
permit for construction will continue to be null and void if the construction project is not
accepted by County and City for the proposed improvement to be served by sewer or if
the County or City voids or cancels either the application of permit for construction of
the proposed improvement to be served by sewer.
SCHEDULE:
COSTS:
ACCOUNT NO:
BUDGETED AMOUNT REMAINING:
ATTACHMENTS: Ordinance No. 520 -10
—29—
Tim Bledsoe
February 4, 2010
Page 2
CONCURRENCE WITH REQUESTED ACTION: CATEGORY: Sewer
GENERAL MANAGER: YES 1 - NO
CHIEF FINANCIAL OFFICER: YES ;i0 NO
-30-
ORDINANCE NO. 520 -10
AN ORDINANCE OF THE SOUTH TAHOE PUBLIC UTILITY DISTRICT
AMENDING SECTION 4.2.10 AND ADDING SECTION 4.5.13 TO THE
ADMINISTRATIVE CODE REGARDING TIME LIMITS ON SEWER PERMITS
BE IT ENACTED by the Board of Directors of the South Tahoe Public Utility
District, County of El Dorado, State of California, as follows:
SECTION 1 POLICY AND PURPOSE
The purpose of this Ordinance is to adopt certain changes to the Administrative
Code regarding time limits for permits allowing connection to the District's sewer
system.
SECTION II — DEFINITIONS
For the purposes of this Ordinance, the terms used herein are defined as follows:
A. The District — The South Tahoe Public Utility District.
B. The Board — The Board of Directors of the South Tahoe Public Utility
District.
C. Administrative Code — The compilation and codification of all of the
Administrative, Water, Sewer, Street Lighting and Groundwater
Management Plan Ordinances of the District, which establish the authority
and the principles for the decisions of the District, and provide the public
with guidelines applicable to District operations.
SECTION III — FINDINGS
The Board of Directors of the South Tahoe Public Utility District, County of El
Dorado, State of California, make the following findings:
1. The District allows connection to its sewer system pursuant to the
applicable provisions of the Ordinances, rules, and regulations of the District and
specifications for sewer service.
2. The Administrative Code presently does not limit the time in which the
holder of a permit to connect to the District's sewer system must make such connection.
As a result, there are many outstanding permits pursuant to which connection has not
been made.
3. There has been confusion among those holding outstanding permits as to
whether their permits are subject to changes in the District's Ordinances, rules, and
regulations and specifications for sewer service between the time the permit is issued and
connection to the District's Sewer System is accomplished.
-31-
4. The proposed amendment is designed to make clear to which of the
District's Ordinances, rules, and regulations and specifications for sewer service a permit
is subject.
5. The proposed amendment will aid in the reduction of outstanding permits
by limiting the time frame in which a permittee may connect to the District's sewer
system pursuant to the District's Ordinances, rules, and regulations and specifications for
sewer service at the time the permit was issued.
6. The proposed amendment is intended to provide the holders of outstanding
permits a reasonable time to complete connection to the District's sewer system, pursuant
to a defined set of District Ordinances, rules, and regulations and specifications for sewer
service.
7. The Board has determined that it is in the best interest of the health and
safety of District residents to adopt an ordinance to amend certain provisions of the
Administrative Code regarding permits for connection to the District's Sewer System.
SECTION IV — AMEND SECTION 4.2.10 OF THE ADMINISTRATIVE CODE
Administrative Code Section 4.2.10 to be amended as follows:
4.2.10 Time Limits On Sewer Permits.
(a) A permit for construction of a sewer lateral shall permit the connection to the
District's sewer service, in accordance with the applicable provisions of the Ordinances,
rules, and regulations of the District and specifications for sewer service in effect at the
date of permitting, for a period of three (3) years from the date the permit is issued. If, at
the expiration of the three (3) year initial permit term, the permittee has yet to construct
the permitted connection to the District's sewer system, the permittee may extend the
permit term for an additional one (1) year term (the "Extension Term "), provided that the
permittee pays the required administrative fee. (Refer to Section 4.5.13 — Sewer Rate
Schedule No. 7.) If, at the expiration of any one (1) year Extension Term, the permittee
has yet to construct the permitted connection to the District's sewer system, the permittee
may extend the permit term for an additional one (1) year Extension Term, provided that
the permittee pays the required administrative fee. (Refer to Section 4.5.13 — Sewer Rate
Schedule No. 7.) Any permit extended pursuant to this subsection shall be subject to the
terms of the District's Administrative Code and regulations in effect at the date of
extension.
(b) Those permits for construction of a sewer lateral that have been issued prior to
the effective date of Ordinance No. 520 -10 shall permit the connection to the District's
sewer service, in accordance with applicable provisions of the Ordinances, rules, and
Ordinance No. 520 -10
Time Limits on Sewer Permits
Page 2
-32-
regulations of the District and specifications for sewer service in effect at the date of
permitting, for a period of three (3) years from the effective date of Ordinance No. 520-
10. If, at the expiration of this three (3) year term, the permittee has yet to construct the
permitted connection to the District's sewer system, the permittee may extend the permit
term for an additional one (1) year Extension Term, provided that the permittee pays the
required administrative fee. (Refer to Section 4.5.13 — Sewer Rate Schedule No. 7.). If,
at the expiration of any one (1) year Extension Term, the permittee has yet to construct
the permitted connection to the District's sewer system, the permittee may extend the
permit term for an additional one (1) year Extension Term, provided that the permittee
pays the required administrative fee. (Refer to Section 4.5.13 — Sewer Rate Schedule No.
7.) Any permit extended pursuant to this subsection shall be subject to the terms of the
District's Administrative Code and regulations in effect at the date of extension.
(c) If, upon the expiration of any permit term, including, any Extension Term, as
applicable, the permittee has not connected to the District's sewer service, and the permit
holder fails to extend the permit, as provided for in section (a) or section (b), above, the
permit shall be suspended, and no connection to the District's sewer system shall be
made thereunder, until the permittee extends the permit term by an additional one (1)
year Extension Term and pays the required administrative fee for each full calendar year
that has passed since the expiration of the prior three (3) year permit term or one (1) year
Extension Term, as applicable. (Refer to Section 4.5.13 — Sewer Rate Schedule No. 7.)
(d) At any time prior to connection to the District's sewer system, a permittee
may terminate its sewer connection permit and the District shall refund to the permittee
the applicable fee for sewer connection, pursuant to Administrative Code section 4.5,
paid by the permittee upon receipt of its permit. Upon the permittee's termination of the
permit term, the permittee shall not be entitled to the refund of any administrative fees
paid for extension of the permit term, as applicable.
(e) Any permittee may choose to comply with changes in the applicable
provisions of the Ordinances, rules, and regulations of the District and specifications for
sewer service made after the date of permitting but prior to connection to the District's
sewer service.
(f) Notwithstanding the above, a sewer permit for construction of a sewer lateral
will be null and void:
1) If construction project is not accepted by County or City for the proposed
improvement to be served by the sewer; or
2) If the County or City voids or cancels either the application or permit for
construction of the proposed improvement to be served by the sewer.
Ordinance No. 520 -10
Time Limits on Sewer Permits
Page 3
-33-
SECTION IV — ADD SECTION 4.5.13 TO THE ADMINISTRATIVE CODE
4.5.13 — SCHEDULE 7
An administrative fee of One Hundred Fifty Dollars ($150.00) will be collected
for the extension of a sewer permit, pursuant to section 4.2.10.
SECTION V — SEVERABILITY '
If any section, subsection, subdivision, paragraph, sentence, clause or phrase of
this Ordinance and its implementing rules and regulations is for any reason held to be
unconstitutional or invalid, such decision shall not affect the validity of the remaining
portions of this Ordinance or the Administrative Code. The Board of Directors declares
and determines that it would have passed section, subsection, subdivision, paragraph,
sentence, clause or phrase thereof of this Ordinance and its implementing rules and
regulations and the Administrative Code irrespective of the fact that any one or more
sections, subsections, subdivisions, paragraphs, sentences, clauses or phrases may be
determined to be unconstitutional or invalid.
SECTION VI — EFFECTIVE DATE
This Ordinance amending the above referenced sections to the Administrative
Code shall take effect thirty days after its passage.
PASSED AND ADOPTED the Board of Directors of the South Tahoe Public
Utility District at its duly held regular meeting on the 4th day of February, 2010 by the
following vote:
AYES:
NOES:
ABSENT:
Dale Rise, President
South Tahoe Public Utility District
ATTEST:
Kathy Sharp, Clerk of the Board
Ordinance No. 520 -10
Time Limits on Sewer Permits
Page 4
-34-
General Manager
Richard H. Solbrig
,� . Directors
%/ ''. ,w S o u o e Chris Cefal
,';;/ ''�" - ^�"',. James R. Jones
� -m ti ' ' :. s /�`'` Ut � e D j • ,r. it s ct Mary Lou Mosbacher
Pu V District Dale Rise
Eric Schafer
1275 Meadow Cruet Chive • math Lake Tahoe • CA 86150
Phone 550 544-6474 74 • Fax 630 541 -0614
BOARD AGENDA ITEM 6b
TO: Board of Directors
FROM: Julie Ryan, Senior Engineer
MEETING DATE: February 4, 2010
ITEM — PROJECT NAME: Headworks Replacement Project — Phase 1
REQUESTED BOARD ACTION: Authorize staff to reject all bids, modify bid
documents and rebid the project.
DISCUSSION: On December 16, 2009, twenty -five (25) general contractors attended
the mandatory pre -bid conference for the above project. Bids for the project were
opened on January 20, 2010. Four (4) bids were received. A summary of all bids is
attached.
Staff and legal counsel believe that it is in the best interests of the District to reject all
bids received for the project and to re -bid the project, beginning February 5, 2010. The
Public Contract Code, as well as the District's own contract language, provide the
District with discretion to reject all bids received on a project when the Board determines
that it is in the best interest of its customers. In this case:
1) The District's project bid documents contained internal inconsistencies regarding
the submission requirements for the bid. This has apparently led to confusion
among bidders, given that no two bidders' submissions were the same.
2) None of the bids received meet the funding requirements, and accepting any of
the bids would jeopardize the funding for the project.
To provide a fair and competitive bidding environment, consistent with the intent of the
Public Contract Code and District policies, Staff and legal counsel recommend that the
Board direct staff to reject all bids, modify the bid documents as needed, and rebid the
project.
Re- bidding the project will not significantly change the timeline for construction. With
Board approval, the revised schedule for bidding and project completion will be as
follows:
-35-
Julie Ryan
February 4, 2010
Page 2
Board authorize to bid February 4, 2010
Advertise February 5 to March 10, 2010
Mandatory Pre -Bid February 16, 2010
Second site visit February 23, 2010
Bid Opening March 10, 2010
Board Approval March 18, 2010
Notice to Proceed April 8, 2010
Contractor Mobilization May 3, 2010
Project Complete October 15, 2010
SCHEDULE: As soon as possible
COSTS: Engineers estimate is $1,364,085
ACCOUNT NO: 1029 -8033
BUDGETED AMOUNT REMAINING: $1,300,000 included in the 2010 /11 proposed
budget
ATTACHMENTS: Summary of Bids.
CONCURRENCE WITH REQUESTED ACTION: CATEGORY: Sewer
GENERAL MANAGER: YES Lo • NO
CHIEF FINANCIAL OFFICER: YES .. NO
-36-
SOUTH TAHOE PUBI
HEADWORKS REPLACEMENT
BID St
Engineer's Est. Thomas Haan Co., Inc.
Item Description Unit QTY Amount Unit Price Amount
1 Mobilization/demobilization
incldg bonds, insurance, clean utLS 1 $124,010.00 $27,260.00 $27,260. s •
2 Provide, install, maintain Erosion
Control complete and in place LS 1 $10,000.00 $6,800.00 $6,800. • •
Pavement Saw Cut and
3 Removal, inddg all labor,
materials, equipment, etc. SF 8,845 $46,200.00 $1.30 $11,498. •
Shoring & worker Safety inddg
4 labor, materials tools, equip, etc LS 1 $105,000.00 $159,744.00 $159,744.11
5 Dewatering, inclg labor,
materials, equip., etc. LS 1 $50,000.0C $10,000.00 $10,000.11
Hazardous Material Abatement -
6 Asbestos Wall Materials -
indudg removal and proper
disposal LS 1 $15,000.00 $2,500.00 $2,500.••
Hazardous Material Abatement -
7 Asbestos Joint Materials, inddg
removal and proper disposal LS 1 $15,000.00 $26,800.00 $26,800.1.
Hazardous Material Abatement -
8 Lead Paint Removal - inddg
removal and disposal LS 1 $15,000.00 $27,200.00 $27,200. • I
Hazarous Mate Abatement -
PCB and Mercury Material -
9 indudg removal and proper
disposal LS 1 $5,000.00 $2,800.00 $2,800.1 •
Hazardous Material Abatement -
10 Asbestos Roofing Materials -
inddg removal and proper
disposal LS 1 $20,000.0C $14,200.00 $14,200.11
Yard Piping Demolition on plans,
11 inddg capping, removing LS 1 $50,000.00 $64,300.00 $64,300.0.
Incineration Building Demo
(above grade) inddg structural,
12 mechanical, electrical and
instrumentation demo, disposal
and off-haul LS 1 $275,000.00 $48,160.00 $48,160.14
Incineration Building Demo
(below grade)inddg structural,
13 mechanical, electrical,
instrumentation demo, disposal
and off -haul LS 1 $125,000.00 $48,160.00 $48,160.10
Ume Mud Thickener (below
14 grade) inddg excavation,
mechanical and structural demo,
disposal and off -haul. LS 1 $100,000.00 $12,850.00 $42,850.14
15 Over Excavatalon and Off Haul
inddg excavation and off haul CY 1,830 $91,500.00 $15.40 $28,182.0 •
Over Excavation and Stockpiling
16 (reusable soil) incldg excavation
and stockpiling CY 610 $15,250.00 $22.10 $13,481.11
Structural Fill Material (Import
Soil) to backfifl in excavation w/in
incinerator bldg and over exc.
area inddg importing, placement
17 & compaction CY 3,057 $152,850.0C $14.40 $44,020.: •
Bac kfill and Compaction to
backfill in excavation wfin
18 incinerator bldg and over exc.
Area inddg importing, placement
and compaction. CY 3,667 $91,675.00 $7.85 $28,785.9
Yard Piping Repl. shown on
19 plans, inddg piping, badcfill,
placement and compaction LS 1 $15,000.00 $25,240.00 $25,240.1 •
20 Provide Fine Grading for site LS 1 $10,000.00 $4,000.00 $4,000.1 •
Pavement Restoration inddg all
21 labor, materials, tools, equip and
incidentals; 7 _ SF 3,260 $32,600.00 $6.60 $21,516. • •
TOTALS per DISTRICT REVIEW & CALCULATION: $1,364,085.00 $627,498.2
TOTALS as WRITTEN IN BID RECEIVED: Same
UTILITY DISTRICT'S
LASE I DEMOLITION PROJECT
NARY
<.G. Walters Construction Evans Brothers, Inc. Bowen Engineering & Envlron.
Init Price Amount Unit Price Amount Unit Price Amount
30,000.00 130,000.00 132,000.00 132,000.00 170,000.00 570,000.00
10,000.00 110,000.00 15,000.00 15,000.00 125,000.00 125,000.00
1.00 $8,845.00. 10.45 13,980.25 12.83 125, 031.35
135,000.00 $135,000.0C 1181,800.00 1181,800.00 135,000.00 135,000.00
15,000.00 115,000.00 114,000.00 114,000.00 130,000.00 130,000.00
3,500.00 13,500.00 17,800.00 17,800.00k, 110,000.00 $10,000.00
63,800.00 163,800.00 198,600.00 198,600.00 110,000.00 , $10,000.0C
64,000.00 164,000.00 /48,000.00 $48,000.00 120,000.00 $20,000.00
7,000.00 17,000.00 12,000.00 12,000.00 15,000.00 15,000.00
15,000.00 115,000.00 135,000.00 135,000.00 115,000.00 $ 15,000.00
43,400.00 $43,400.00 120,000.00 120,000.00 1100,000.00 $100,000.0C
36,600.00 $36,600.04 115,600.00 115,600.00 175,000.00 175,000.00
38,600.00 /36,600.00 119,000.00 119,000.00 175,000.00 175,000.00
17,000.00 $17,000.00 *19,000.00 119,000.00 135,000.00 135,000.00
45.00 182,350.00 110.00 118,309.00 115.03 $27,504.90
10.00 16,100.00 110.00 16,100.00 18.20 $5,002.00
20.00 161,140.00 147.00 $143,679.0C 114.72 144,999.04
8.00 129,338.00 18.00 129,336.00 15.00 118,335.00
60,000.00 160,000.00 157,500.00 157,500.00 1125,000.00 1125,000.0C
4,500.00 14,500.00 19,780.00 19,780.00 110,000.00 110,000.00
6.00 $19,560.00 16.96 122,889.80 110.90' 8- 132,600.00
$748,731.00 1789,164.85 1793,47229
Same 1789,195.00 793,435.00
General Manager
Richard H. Solbrig
,Y , _ ... , % ;t,. Directors
''' ,r,. ,,,,� `. o T a o James R. Jones
r Mks . ` . e:= ,� •//'""�� Utility s (•/ Mary Lou M osbacher
• Public Distric V Dale Rise
� Eric Schafer
1275 Meadow Crest Drive • South Lake Tahoe • CA 96150
Phone 534 544 -6474 • Fax 550 541-0614
BOARD AGENDA ITEM 6c
TO: Board of Directors
FROM: Accounts Payable
MEETING DATE: February 4, 2010
ITEM — PROJECT NAME: Payment of Claims
REQUESTED BOARD ACTION: Approve Payment
DISCUSSION: The Payment of Claims was not available when this agenda was
published. It will be distributed prior to, and at the Board meeting.
SCHEDULE:
COSTS:
ACCOUNT NO:
BUDGETED AMOUNT REMAINING:
ATTACHMENTS: To be distributed prior to, and at the Board meeting.
CONCURRENCE WITH REQUESTED ACTION: CATEGORY: General
GENERAL MANAGER: YES NO
CHIEF FINANCIAL OFFICER: YES NO
-39-
PAYMENT OF CLAIMS
FOR APPROVAL
February 4, 2010
Payroll 1/27/10 427,797.63
Payroll 1/14/10 88,130.80
Total Payroll 515,928.43
BNY Mellon Trust Company 72,731.80
CDS- health care payments 41,633.71
ADP 1,768.00
Brownstein /Hyatt/Farber /Schreck legal services 23,286.13
Bank of America 0.00
Union Bank 371,425.72
Total Vendor EFT 510,845.36
Accounts Payable Checks -Sewer Fund 294,468.37
Accounts Payable Checks -Water Fund 482,307.72
Accounts Payable Checks - Self - funded Insurance 30,438.20
Accounts Payable Checks - Grants Fund 0.00
Total Accounts Payable 807,214.29
Grand Total 1,833,988.08
Payroll EFTs & Checks 1/27/10 1/14/10
EFT AFLAC Medical & Dependent Care 812.18 0.00
EFT CA Employment Taxes & W/H 18,452.65 5,999.62
EFT Federal Employment Taxes & W/H 92,684.44 33,375.78
EFT CaIPERS Contributions 73,911.48 0.00
EFT Great West Deferred Comp 18,506.79 0.00
EFT Stationary Engineers Union Dues 2,421.58 0.00
EFT United Way Contributions 187.00 0.00
EFT Employee Direct Deposits 207,025.38 48,755.40
CHK Employee Garnishments 1,459.84 0.00
CHK Employee Paychecks 12,336.29 0.00
Total 427,797.63 88,130.80
PAYMENT OF CLAIMS
Vendor Name Department / Proj Name Description Acct# / PrQj Code Amount Check Num Tvoe
ACRI, MARK CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: 200.00 AP- 00074891 MW
ACWA HEALTH BENEFITS AUTHORITY GEN & ADMIN VISION INS 1000 - 2530 2,670.14
Check Total: 2.670.14 AP- 00074892 MW
AECOM USA INC ENGINEERING - REPL GEN, LPPS REPL GEN LPPS 1029 - 8933 - RGLPPS 23,683.43
Check Total: 23,683.43 AP- 00074893 MW
AFLAC GEN & ADMIN SUPP INS W/H 1000 - 2532 864.06
Check Total: 864.06 AP- 00074894 MW
AHERN RENTALS UNDERGROUND REP SAFETY/EQUIP/PHY 1001 - 6075 43.50
Check Total: 43.50 AP- 00074895 MW
AIRVAC INC PUMPS PUMP STATIONS 1002 - 6051 170.40
Check Total: 170.40 AP- 00074896 MW
ALPEN SIERRA COFFEE GEN & ADMIN OFC SUPPLY ISSUE 1000 - 6081 256.50
Check Total: 256.50 AP- 00074897 MW
AMEC EARTH & ENVIRONMENTAL INC ENGINEERING - ECHO TANK REPL TANK, ECHO 2029 - 8809 - ECHOTK 757.64
Check Total: 757.64 AP- 00074898 MW
AMERICAN BANKERS INS CO GEN & ADMIN INSURANCE PPD 1000 - 0301 20,833.50
AMERICAN BANKERS INS CO GEN & ADMIN INSURANCE PPD 2000 - 0301 20,833.50
Check Total: 41.667.00 AP- 00074899 MW
AMERICAN CHEMICAL SOCIETY LABORATORY DUES/MEMB/CERT 1007 - 6250 42.50
AMERICAN CHEMICAL SOCIETY LABORATORY DUES/MEMB/CERT 2007 - 6250 42.50
Check Total: 85.00 AP- 00074900 MW
AMERIGAS DIAMOND VLY RNCH PROPANE 1028 - 6360 730.92
Check Total: 730.92 AP- 00074901 MW
AMERIPRIDE UNIFORM SERVICES GEN & ADMIN UNIFORM PAYABLE 1000 - 2518 976.94
Check Total: 976.94 AP- 00074902 MW
ARNOLD MACHINERY EQUIPMENT REP AUTOMOTIVE 1005 - 6011 789.73
Check Total: 789.73 AP- 00074903 MW
AT&T /CALNET 2 GEN & ADMIN TELEPHONE 1000 - 6310 8.17
AT&T /CALNET 2 PUMPS TELEPHONE 1002 - 6310 82.18
AT&T /CALNET 2 OPERATIONS TELEPHONE 1006 - 6310 30.38
User: THERESA
Page: 1 Current Date: 02/02/2010
Report: OH_PMT_CLAIMS_BK Current Time: 17:13:49
Vendor Name
AT&T / CALNET 2
AT&T /CALNET 2
AWWA
AWWA CAL -NEV SECTION
BAILEY, CHERYL
BI STATE PROPANE
BI STATE PROPANE
BING MATERIALS
BING MATERIALS
BIRD, HAL
BLUE RIBBON TEMP PERSONNEL
BLUE RIBBON TEMP PERSONNEL
BOEHME, MICHAEL
BRIGHT, JONELLE
BROWN & CALDWELL CONSULTANTS
User: THERESA
Report: OH_PMT_CLAIMS BK
Department / Proj Name
GEN & ADMIN
PUMPS
CUSTOMER SERVICE
LABORATORY
CUSTOMER SERVICE -WTR CONS PROG
UNDERGROUND REP
EQUIPMENT REPAIR
GEN & ADMIN - WTRLN, TATA
ENGINEERING - WTRLN, TATA
DIAMOND VLY RNCH
CUSTOMER SERVICE
CUSTOMER SERVICE
CUSTOMER SERVICE - WTR CONS PROG
CUSTOMER SERVICE - WTR CONS PROG
ENGINEERING - FILTER ASSMNT
BROWN & CALDWELL CONSULTANTS ENGINEERING - ANGORA TNK REPL
BROWN & CALDWELL CONSULTANTS ENGINEERING - ECHO TANK REPL
BULL, SUSANNE CUSTOMER SERVICE -WTR CONS PROG
BURTRAW, MELVIN J CUSTOMER SERVICE - WTR CONS PROG
PAYMENT OF CLAIMS
Description
TELEPHONE
TELEPHONE
DUES/MEMB /CERT
DUES/MEMB /CERT
WTR CONS EXPENSE
SMALL TOOLS
AUTOMOTIVE
CONST RETAINAGE
WTRLN, TATA LN
TRAVELIMEETINGS
CONTRACT SERVICE
CONTRACT SERVICE
WTR CONS EXPENSE
WTR CONS EXPENSE
REHAB FLTR 5&6
TANK, ANGORA
TANK, ECHO
WTR CONS EXPENSE
WTR CONS EXPENSE
Page: 2
Acct# / Proj Code
2000 - 6310
2002 - 6310
2038 - 6250
2007 -6250
Check Total:
Check Total:
Check Total:
2038 - 6660 - WCPROG
Check Total:
2001 - 6073
2005 -6011
Check Total:
2000 - 2605 - TATAWL
2029 - 8866 - TATAWL
1028 -6200
1038 - 4405
2038 -4405
Check Total:
Check Total:
Check Total:
2038 - 6660 - WCPROG
Check Total:
2038 - 6660 - WCPROG
Check Total:
1029 - 8066 - FILTER
2029 - 7064 - ANGOTK
2029 - 8809 - ECHOTK
Check Total:
2038 - 6660 - WCPROG
Check Total:
2038 - 6660 - WCPROG
Current Date: 02/02/2010
Current Time: 17:13:49
Amount Chord al= T
8.17
35.97
164.87 AP- 00074904
165.00
165.00 AP- 00074905
150.00
150.00 AP- 00074906
200.00
200.00 AP- 00074907
172.48
67.43
239.91 AP- 00074908
36,075.95
24,293.95
60 369.90 AP- 00074883
183.00
183.00
680.40
680.40
1,360.80 AP -00074910
200.00
200.00 AP- 00074911
200.00
200.00
633.42
11,438.68
11,438.69
23.510.79 AP- 00074913
200.00
200.00 AP- 00074914
200.00
AP -00074909
AP- 00074912
MW
MW
MW
MW
MW
MW
MW
MW
MW
MW
MW
MW
Vendor Name
ACRI, MARK
PAYMENT OF CLAIMS
Department / Proi Name Descrivtion Acct# / Proj Code Amount Check Num Tvve
CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: Y00.00 AP-00074891 MW
ACWA HEALTH BENEFITS AUTHORITY GEN & ADMIN VISION INS 1000 - 2530 2,670.14
Check Total: 2.670.14 AP- 00074892 MW
AECOM USA INC ENGINEERING - REPL GEN, LPPS REPL GEN LPPS 1029 - 8933 - RGLPPS 23,683.43
Check Total: 23.683.43 AP- 00074893 MW
AFLAC GEN & ADMIN SUPP INS WM 1000 - 2532 864.06
Check Total: 864.06 AP- 00074894 MW
AHERN RENTALS UNDERGROUND REP SAFETY/EQUIP/PHY 1001 - 6075 43.50
Check Total: 43.50 AP-00074895 MW
AIRVAC INC PUMPS PUMP STATIONS 1002 - 6051 170.40
Check Total: 170.40 AP-00074896 MW
ALPEN SIERRA COFFEE GEN & ADMIN OFC SUPPLY ISSUE 1000 - 6081 256.50
Check Total: 256.50 AP-00074897 MW
AMEC EARTH & ENVIRONMENTAL INC ENGINEERING - ECHO TANK REPL TANK, ECHO 2029 - 8809 - ECHOTK 757.64
Check Total: 757.64 AP- 00074898 MW
AMERICAN BANKERS INS CO GEN & ADMIN INSURANCE PPD 1000 - 0301 20,833.50
AMERICAN BANKERS INS CO GEN & ADMIN INSURANCE PPD 2000 - 0301 20,833.50
Check Total: 41.667.00 AP- 00074899 MW
AMERICAN CHEMICAL SOCIETY LABORATORY DUES/MEMB/CERT 1007 - 6250 42.50
AMERICAN CHEMICAL SOCIETY LABORATORY DUES/MEMB /CERT 2007 - 6250 42.50
Check Total: 85.00 AP- 00074900 MW
AMERIGAS DIAMOND VLY RNCH PROPANE 1028 - 6360 730.92
Check Total: 730.92 AP-00074901 MW
AMERIPRIDE UNIFORM SERVICES GEN & ADMIN UNIFORM PAYABLE 1000 - 2518 976.94
Check Total: 976.94 AP- 00074902 MW
ARNOLD MACHINERY EQUIPMENT REP AUTOMOTIVE 1005 - 6011 789.73
Check Total: 78173 AP- 00074903 MW
AT&T /CALNET 2 GEN & ADMIN TELEPHONE 1000 - 6310 8.17
AT&T / CALNET 2 PUMPS TELEPHONE 1002 - 6310 82.18
AT&T / CALNET 2 OPERATIONS TELEPHONE 1006 - 6310 30.38
User: THERESA
Page: 1 Current Date: 02/02/2010
Report: OH_PMT_CLAIMS_BK Current Time: 17:26:24
PAYMENT OF CLAIMS
Vendor Name Department / Proj Name Description Acct# / Proj Code Amount Check Num Iypg
AT &T /CALNET 2 GEN & ADMIN TELEPHONE 2000 - 6310 8.17
AT &T /CALNET 2 PUMPS TELEPHONE 2002 - 6310 35.97
Check Total: 164.87 AP- 00074904 MW
AWWA CUSTOMER SERVICE DUES/MEMB /CERT 2038 - 6250 165.00
Check Total: 165.00 AP- 00074905 MW
AWWA CAL -NEV SECTION LABORATORY DUES/MEMB /CERT 2007 - 6250 150.00
Check Total: 150.00 AP- 00074906 MW
BAILEY, CHERYL CUSTOMER SERVICE -WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: 200.00 AP- 00074907 MW
BI STATE PROPANE UNDERGROUND REP SMALL TOOLS 2001 - 6073 172.48
BI STATE PROPANE EQUIPMENT REPAIR AUTOMOTIVE 2005 - 6011 67.43
Check Total: 239.91 AP- 00074908 MW
BING MATERIALS GEN & ADMIN - WTRLN, TATA CONST RETAINAGE 2000 - 2605 - TATAWL 36,075.95
BING MATERIALS ENGINEERING - WTRLN, TATA WTRLN, TATA LN 2029 - 8866 - TATAWL 24,293.95
Check Total: 60.369.90 AP- 00074883 MW
BIRD, HAL DIAMOND VLY RNCH TRAVEL/MEETINGS 1028 - 6200 183.00
Check Total: 183.00 AP- 00074909 MW
BLUE RIBBON TEMP PERSONNEL CUSTOMER SERVICE CONTRACT SERVICE 1038 - 4405 680.40
BLUE RIBBON TEMP PERSONNEL CUSTOMER SERVICE CONTRACT SERVICE 2038 - 4405 680.40
Check Total: 1.360.80 AP- 00074910 MW
BOEHME, MICHAEL CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: 200.00 AP- 00074911 MW
BRIGHT, JONELLE CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: 200.00 AP- 00074912 MW
BROWN & CALDWELL CONSULTANTS ENGINEERING - FILTER ASSMNT REHAB FLTR 5 &6 1029 - 8066 - FILTER 633.42
BROWN & CALDWELL CONSULTANTS ENGINEERING - ANGORA TNK REPL TANK, ANGORA 2029 - 7064 - ANGOTK 11,438.68
BROWN & CALDWELL CONSULTANTS ENGINEERING - ECHO TANK REPL TANK, ECHO 2029 - 8809 - ECHOTK 11,438.69
Check Total: 23.510.79 AP- 00074913 MW
BULL, SUSANNE CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: 200.00 AP- 00074914 MW
BURTRAW, MELVIN J CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
User: THERESA
Page: 2 Current Date: 02/02/2010
Report: OH_PMT_CLAIMS_BK Current Time: 17:26:24
Vendor Name
CAHILL-O'BRIEN, 11M
CALUAN, JERALEE
CALLIAN, JERALEE
CAMPBELL CONSTRUCTION CO INC
CAMPBELL CONSTRUCTION CO INC
CARNEGGIE, DAVID
CAROLLO ENGINEERS
CAROLLO ENGINEERS
CARROLL, SCOTT
CASA
CDS GROUP HEALTH
CDW - G CORP
CDW - G CORP
CITY OF SOUTH LAKE TAHOE
CRAIG, CAROLYN
CREEK ENVIRONMENTAL LABS
CREEK ENVIRONMENTAL LABS
CREEK ENVIRONMENTAL LABS
Department / Proj Name
CUSTOMER SERVICE - WTR CONS PROG
CUSTOMER SERVICE
CUSTOMER SERVICE
GEN & ADMIN - WT METERING PRJ
ENGINEERING - WT METERING PRJ
CUSTOMER SERVICE - WTR CONS PROG
ENGINEERING - HEADWORKS
ENGINEERING - TWIN PEAKS BS
CUSTOMER SERVICE - WTR CONS PROG
BOARD OF DIR
SELF FUNDED INS
ENGINEERING
ENGINEERING
UNDERGROUND REP
CUSTOMER SERVICE - WTR CONS PROG
LABORATORY - BKRFLD TRTMT EXP
LABORATORY - HERBST
LABORATORY
PAYMENT OF CLAIMS
User: THERESA Page: 3
Report: OH_PMT_CLAIMS_BK
Description
WTR CONS EXPENSE
TRAVEUMEETINGS
TRAVELIMEETINGS
CONST RETAINAGE
WTR METERING/NEW
WTR CONS EXPENSE
HDWKS IMP PROJ
BSTR, TWN PEAKS
WTR CONS EXPENSE
DUESIMEMB/CERT
ADMIN FEE
OFFICE SUPPUES
OFFICE SUPPUES
PIPEICVRS/MHLS
WTR CONS EXPENSE
MONITORING
MONITORING
MONITORING
Acct# / Proj Code
2038 - 6660 - WCPROG
Check Total:
1038-6200
2038-6200
2000 - 2605 - METERS
2029 - 7078 - METERS
Check Total:
2038 - 6660 - WCPROG
Check Total:
1029 - 8033 - HDWORK
2029 - 7070 - TPBSTR
Check Total:
2038 - 6660 - WCPROG
1019-6250
3000 -6741
1029 -4820
2029 - 4820
2001-6052
2038 - 6660 - WCPROG
2007 - 6110 - BKRFLD
2007 - 6110 - HERBST
2007 -6110
Check Total:
Check Total:
Check Total:
Check Total:
Check Total:
Check Total:
Check Total:
Check Total:
Check Total:
Current Date: 02/02/2010
Current Time: 17:26:24
Amount Check Num DM
200.00 AP- 00074915 MW
200.00
200.00 AP- 00074916 MW
62.00
62.00
124.00 AP- 00074917 MW
- 1,750.00
17,500.00
15.750.00 AP- 00074918 MW
200.00
200.00 AP- 00074919 MW
91,139.20
14,142.00
105.281.20 AP- 00074920 MW
200.00
200.00 AP- 00074921 MW
15,000.00
15.000.00 AP -00074922 MW
2,954.75
2.954.75 AP- 00074923 MW
87.75
87.73
175.48 AP- 00074924 MW
1,200.00
1.200.00 AP-00074925 MW
200.00
200.00 AP- 00074926 MW
190.00
190.00
190.00
570.00 AP-00074927
MW
PAYMENT OF CLAIMS
Vendor Name Department / Proj Name Description Acct# / Proj Code Amount Check Num Tyne
CSDA BOARD OF DIR DUES/MEMB /CERT 1019 - 6250 2,044.00
CSDA BOARD OF DIR DUES/MEMB /CERT 2019 - 6250 2,044.00
Check Total: 4.088.00 AP- 00074928 MW
CWEA UNDERGROUND REP DUES/MEMB /CERT 1001 - 6250 79.00
CWEA ELECTRICAL SHOP DUES/MEMB /CERT 1003 - 6250 132.00
CWEA CUSTOMER SERVICE DUES/MEMB /CERT 1038 - 6250 132.00
CWEA UNDERGROUND REP DUES/MEMB /CERT 2001 - 6250 132.00
Check Total: 475.00 AP- 00074929 MW
DANIEL, NANCY CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: 200.00 AP- 00074930 MW
DEGRAAF, DALE CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: 200.00 AP- 00074931 MW
DENTON, D. E. CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: 400.00 AP- 00074932 MW
EL DORADO COUNTY ENGINEERING - ECHO TANK REPL TANK, ECHO 2029 - 8809 - ECHOTK 50.00
Check Total: 50.00 AP- 00074933 MW
EL DORADO COUNTY PUMPS OPERATING PERMIT 1002 - 6650 250.00
EL DORADO COUNTY PUMPS OPERATING PERMIT 2002 - 6650 1,250.00
Check Total: 1.500.00 AP- 00074934 MW
ELDER, VYUE JOY CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: 200.00 AP- 00074935 MW
ENTRIX INC ENGINEERING - SUT WELL REDRILL SUT WELL REDRILL 2029 - 8463 - RWSUTR 3,177.20
Check Total: 3,177.20 AP- 00074936 MW
ETS LABORATORY MONITORING 1007 - 6110 992.25
Check Total: 992.25 AP- 00074937 MW
EVANS, KAI CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: 200.00 AP- 00074938 MW
FEDEX PUMPS PUMP STATIONS 1002 - 6051 62.59
FEDEX ENGINEERING - WT METERING PRJ WTR METERING/NEW 2029 - 7078 - METERS 6.66
Check Total: 69.25 AP- 00074939 MW
FELICIANO, ROSS CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
User: THERESA Page: 4 Current Date: 02/02/2010
Report: OH_PMT_CLAIMS_BK Current Time: 17:26:24
Vendor Name
FERGUSON ENTERPRISES INC.
FERGUSON ENTERPRISES INC.
FERGUSON ENTERPRISES INC.
FISHER SCIENTIFIC
FISHER SCIENTIFIC
GCS SERVICE INC
GCS SERVICE INC
GERLAND, BARBARA
GIBSON I11, HARRY R.
GRAINGER
GRAINGER
GRAINGER
GRAYBAR ELECTRIC COMPANY INC
GROVE MADSEN INDUSTRIES INC
HARTFORD, THE
HARTFORD, THE
HARTZELL, JOHN
HAUGE BRUECK ASSOCIATES LLC
HAVEN, NICK
Department / Proj Name
HEAVY MAINT
HEAVY MAINT
HEAVY MAINT
LABORATORY
LABORATORY
LABORATORY
LABORATORY
CUSTOMER SERVICE - WTR CONS PROG
CUSTOMER SERVICE - WTR CONS PROG
ELECTRICAL SHOP
HEAVY MAINT
EQUIPMENT REPAIR
ELECTRICAL SHOP
ELECTRICAL SHOP
GEN & ADMIN
GEN & ADMIN
CUSTOMER SERVICE - WTR CONS PROG
ENGINEERING - REPL GEN, LPPS
CUSTOMER SERVICE - WTR CONS PROG
PAYMENT OF CLAIMS
Description
BUILDINGS
GROUNDS & MNTC
SHOP SUPPLIES
LABORATORY EQUIP
LABORATORY EQUIP
LABORATORY EQUIP
LABORATORY EQUIP
WTR CONS EXPENSE
WTR CONS EXPENSE
PRIMARY EQUIP
PRIMARY EQUIP
AUTOMOTIVE
PUMP STATIONS
LUTHER PASS
UFE INS
LTD, UNION
User: THERESA Page: 5
Report: OH_PMT_CLAIMS_BK
WTR CONS EXPENSE
REPL GEN LPPS
WTR CONS EXPENSE
Acct# / Proj Code
1004 -6041
1004 - 6042
1004 - 6071
1007-6025
2007-6025
1007 - 6025
2007 - 6025
2038 - 6660 - WCPROG
Check Total:
Check Total:
Check Total:
Check Total:
Check Total:
2038 - 6660 - WCPROG
Check Total:
1003 -6021
1004 - 6021
2005 -6011
1003-6051
1003-6048
1000 -2512
1000 - 2539
2038 - 6660 - WCPROG
2038 - 6660 - WCPROG
Check Total:
Check Total:
Check Total:
Check Total:
Check Total:
1029 - 8933 - RGLPPS
Check Total:
Current Date: 02/02/2010
Current Time: 17:26:24
Amount Check Num Iyeg
200.00 AP- 00074940 MW
134.34
45.56
56.30
236.20 AP- 00074941
123.77
123.78
247.55 AP- 00074942
165.48
150.90
316.38 AP- 00074943
200.00
200.00 AP- 00074944
200.00
200.00 AP- 00074945
196.93
51.81
1,547.40
1.796.14 AP- 00074946
126.87
126.87 AP- 00074947
765.59
765.59 AP- 00074948
2,044.12
2,551.79
4.595.91 AP- 00074949
200.00
200.00 AP- 00074950
6,640.00
6.640.00 AP- 00074951
200.00
MW
MW
MW
MW
MW
MW
MW
M W
MW
MW
Vendor Name Department / Proj Name
PAYMENT OF CLAIMS
HIGH SIERRA BUSINESS SYSTEMS ADMINISTRATION SERVICE CONTRACT
HIGH SIERRA BUSINESS SYSTEMS ADMINISTRATION SERVICE CONTRACT
Description Acct# / Proj Code
1021 -6030
2021-6030
Check Total:
Amount Check Nunl log
200.00 AP-00074952 MW
37.13
37.12
Check Total: 74.25 AP- 00074953 MW
HILL, VICTORIA CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: 200.00 A1 00074954 MW
HUBER, VIRGINIA CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: 200.00 AP- 00074955 MW
HUNTLEY, DENNIS CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: 200.00 AP- 00074956 MW
INSITE LAND SURVEYS ENGINEERING - ECHO TANK REPL TANK, ECHO 2029 - 8809 - ECHOTK 150.00
Check Total: 150.00 AP- 00074957 MW
1WATER INC INFORMATION SYS GIS IMP/UPGR 1037 - 8081 10,435.65
WATER INC INFORMATION SYS ADD'L GIS UC 1037 - 8892 5,219.13
Check Total: 15 AP- 00074958 MW
J &L PRO KLEEN INC FINANCE JANITORIAL SERV 1039 - 6074 1,603.50
J &L PRO KLEEN INC FINANCE JANITORIAL SERV 2039 - 6074 1,603.50
Check Total: 3.207.00 AP- 00074959 MW
JEFFCO INC ADMINISTRATION OFFICE SUPPLIES 1021 -4820 1.95
JEFFCO INC FINANCE OFFICE SUPPLIES 1039 - 4820 3.92
JEFFCO INC ADMINISTRATION OFFICE SUPPUES 2021 - 4820 1.95
JEFFCO INC FINANCE OFFICE SUPPLIES 2039 - 4820 3.93
Check Total: 11.75 AP- 00074960 MW
JINKENS, TERRI CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: 200.00 AP- 00074961 MW
KAELIN, IRENE CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: 200.00 AP- 00074962 MW
KAUFMAN, ROBERT CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: 200.00 AP- 00074963 my/
KELBUS, JIM CUSTOMER SERVICE -WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: 200.00 AP- 00074964 MW
User: THERESA Page: 6 Current Date: 02/02/2010
Report: OH_PMT_CLAIMS_BK Current Time: 17:26:24
Vendor Name
KEN'S TIRE CENTER
User: THERESA
PAYMENT OF CLAIMS
Department / Proj Name Description Acct# / Prpj Code Amount Check Num lype
EQUIPMENT REP AUTOMOTIVE 1005 - 6011 144.13
Check Total: 144.13 AP 00074965 MW
KG WALTERS CONSTRUCTION GEN & ADMIN - ANGORA TNK REPL CONST RETAINAGE 2000 - 2605 - ANGOTK 29,879.47
Check Total: 29.879.47 AP 00074966 MW
KOFFMAN, TONI CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
KRLT FM/KOWL AM DIO - PR EXP- EXTERNAL PUB RELATIONS 1027 - 6620 - PREEXT 1,745.00
KRLT FM/KOWL AM DIO - PR EXP -EXTERNAL PUB RELATIONS 2027 - 6620 - PREEXT 1,745.00
KRLT FM/KOWL AM CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 1,602.00
Check Total: 5.092.00 AP 00074968 MW
KROFTA,CHAD CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: 200.00 AP 00074969 MW
LAWRENCE, GALE CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: Y00.00 AP 00074970 MW
LEUCH, HERMANN CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: 200.00 AP MW
LEXISNEXIS MATTHEW BENDER ADMINISTRATION SUBSCRIPTIONS 1021 -4830 306.75
LEXISNEXIS MATTHEW BENDER ADMINISTRATION SUBSCRIPTIONS 2021 -4830 306.74
Check Total: 613.49 AP 00074972 MW
LONG, WES GEN & ADMIN SUSPENSE 1000 - 2504 936.97
Check Total: 936.97 AP 00074889 MW
LOOMIS FINANCE CONTRACT SERVICE 1039 - 4405 304.30
LOOMIS FINANCE CONTRACT SERVICE 2039 - 4405 304.29
Check Total: 608.59 AP 00074973 MW
LUCAS, CHRIS CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: 200.00 AP 00074974 MW
MC MASTER CARR SUPPLY CO UNDERGROUND REP SHOP SUPPLIES 1001 - 6071 272.55
MC MASTER CARR SUPPLY CO PUMPS PUMP STATIONS 1002 - 6051 233.11
MC MASTER CARR SUPPLY CO PUMPS SHOP SUPPLIES 1002 - 6071 171.15
MC MASTER CARR SUPPLY CO PUMPS SMALL TOOLS 1002 - 6073 241.95
MC MASTER CARR SUPPLY CO HEAVY MAINT SHOP SUPPLIES 1004 - 6071 121.42
Page: 7 Current Date: 02/02/2010
Report: OH_PMT_CLAIMS_BK Current Time: 17:26:24
Check Total: 200.00 AP 00074967 MW
PACIFIC MECHANICAL CORP
PINE CONE ACRE MOTEL
PINKEL,MICHELE
User: THERESA
GEN & ADMIN - WT METERING PRJ
UNDERGROUND REP
ENGINEERING
PAYMENT OF CLAIMS
Vendor Name Department / Proj Name Description Acct# / Proj Code Amount Check Num Iypg
MC MASTER CARR SUPPLY CO HEAVY MAINT IN -PLANT AIR CMP 1004 - 8093 295.47
MC MASTER CARR SUPPLY CO PUMPS SHOP SUPPLIES 2002 - 6071 401.49
MC MASTER CARR SUPPLY CO PUMPS SMALL TOOLS 2002 - 6073 215.55
Check Total: 1.752.49 AP- 00074976 MW
MUELLER, ALAN CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: 200.00 AP- 00074977 MW
MUFFLER PALACE, THE EQUIPMENT REPAIR AUTOMOTIVE 2005 - 6011 104.37
Check Total: 104.37 AP- 00074978 MW
MULLER, NANCY CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: 200.00 AP- 00074979 MW
MWH LABORATORIES ENGINEERING - ARSENIC FACILITY ARSNC TRTMNT 2029 - 8864 - ARSNIC 90.00
Check Total: 90.00 AP- 00074980 MW
NEVADA GENERATOR SYSTEMS EQUIPMENT REP GENERATORS 1005 - 6013 179.00
Check Total: 179.00 AP- 00074981 MW
NORTHWEST HYD. CONSULT INC ENGINEERING - CTC GRNT -BMPs BMP PROJECTS 1029 - 8737 - CTCBMP 6,425.02
NORTHWEST HYD. CONSULT INC ENGINEERING - CTC GRNT -BMPs BMP PROJECTS 2029 - 8745 - CTCBMP 6,425.01
Check Total: 12.850.03 AP- 00074982 MW
NOVALYNX CORP LABORATORY OFFICE SUPPLIES 1007 - 4820 75.18
NOVALYNX CORP LABORATORY OFFICE SUPPLIES 2007 - 4820 75.17
Check Total: 150.35 AP- 00074983 MW
OFFICE DEPOT FINANCE OFFICE SUPPLIES 1039 - 4820
OFFICE DEPOT FINANCE OFFICE SUPPLIES 2039 - 4820
PRAXAIR 174 HEAVY MAINT SHOP SUPPLIES 1004 - 6071
PRAXAIR 174 HEAVY MAINT SAFETY/EQUIP/PHY 1004 - 6075
Check Total:
CONST RETAINAGE 2000 - 2605 - METERS 3,687.65
Check Total: 3.687.65 AP- 00074985 MW
STANDBY ACCOMODA 2001 - 6083 372.50
Check Total: 372.50 AP- 00074986 MW
TRAVEL/MEETINGS 1029 - 6200 43.45
Check Total: 43,45 AP- 00074987 MW
Page: 8 Current Date: 02/02/2010
' Report: OH_PMT_CLAIMS_BK Current Time: 17:26:24
8.92
8.92
17.84 AP- 00074984 MW
26.33
91.00
Vendor Name
PROTO, JEANNE
REED, KATHRYN
PAYMENT OF CLAIMS
Department / Proj Name Description Acct# / Proj Code Amount Check Num
IYe€
Check Total: 117.33 AP- 00074988 MW
CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: 200.00 AP- 00074989 MW
CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: 200.00 AP- 00074990 MW
RELIANCE STANDARD GEN & ADMIN LIFE INS MGMT 1000 - 2525 508.70
RELIANCE STANDARD GEN & ADMIN LNG TRM DIS,MGMT 1000 - 2531 1,261.08
Check Total: 1.769.78 AP- 00074991 MW
RENO GAZETTE - JOURNAL ENGINEERING - REPL GEN, LPPS REPL GEN LPPS 1029 - 8933 - RGLPPS 233.59
Check Total: 233.59 AP- 00074992 MW
RESOURCE DEVELOPMENT INC GEN & ADMIN - TWIN PEAKS BS CONST RETAINAGE 2000 - 2605 - TPBSTR - 4,758.50
RESOURCE DEVELOPMENT INC ENGINEERING - TWIN PEAKS BS BSTR, TWN PEAKS 2029 - 7070 - TPBSTR 47,585.00
Check Total: 42,826.50 AP- 00074993 MW
ROMSOS, JEFFREY SHANE CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: 200.00 AP- 00074994 MW
ROOTX UNDERGROUND REP PIPE/CVRS/MHLS 1001 - 6052 474.00
Check Total: 474.00 AP- 00074995 MW
SCBA SAFETY CHECK INC HEAVY MAINT SAFETY/EQUIP/PHY 1004 - 6075 452.74
Check Total: 452.74 AP- 00074996 MW
SCHAFER, ERIC BOARD OF DIR TRAVEL/MEETINGS 1019 - 6200 1,161.47
Check Total: 1,161.47 AP- 00074997 MW
SHARP, KATHY ADMINISTRATION TRAVEL/MEETINGS 1021 - 6200 30.50
SHARP, KATHY ADMINISTRATION TRAVEL/MEETINGS 2021 -6200 30.50
Check Total: 61.00 AP- 00074998 MW
SHERIDAN, JOHN OPERATIONS TRAVELIMEETINGS 1006 - 6200 520.00
Check Total: 520.00 AP- 00074999 MW
SHERMAN, STEVE CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: Y00.00 AP 00075000 MW
SIERRA CHEMICAL CO OPERATIONS HYPOCHLORITE 1006 - 4755 3,743.96
Check Total: 3.743.96 AP- 00075001 MW
SIERRA PACIFIC POWER GEN & ADMIN ELECTRICITY 1000 - 6330 65,443.71
User: THERESA
Page: 9 Current Date: 02/02/2010
Report: OH_PMT_CLAIMS_BK Current Time: 17:26:24
PAYMENT OF CLAIMS
Vendor Name Department / Pull Name Description Acct# / Proj Code Amount Check Num Type
SIERRA PACIFIC POWER GEN & ADMIN ELECTRICITY 2000 - 6330 26,585.12
Check Total: 92.028.83 AP- 00075002 MW
SIERRA TAHOE READY MIX ENGINEERING - WTRLN, TATA WTRLN, TATA LN 2029 - 8866 - TATAWL 18,397.32
Check Total: 18.397.32 AP- 00074884 MW
SINGER, HAROLD CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: 200.00 AP- 00075003 MW
SOUTHWEST GAS GEN & ADMIN NATURAL GAS 1000 - 6350 190.85
SOUTHWEST GAS GEN & ADMIN NATURAL GAS 2000 - 6350 218.83
Check Total: 409.68 AP- 00075004 MW
SPAULDING, ROBERT C. CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038.6660 - WCPROG 200.00
Check Total: 200.00 AP- 00075005 MW
SPRINGBROOK SOFTWARE INC INFORMATION SYS CONTRACT SERVICE 1037 - 4405 450.00
SPRINGBROOK SOFTWARE INC INFORMATION SYS ADVISORY 1037 - 4440 325.00
SPRINGBROOK SOFTWARE INC INFORMATION SYS SERVICE CONTRACT 1037 - 6030 225.00
SPRINGBROOK SOFTWARE INC INFORMATION SYS CONTRACT SERVICE 2037 - 4405 450.00
SPRINGBROOK SOFTWARE INC INFORMATION SYS ADVISORY 2037 - 4440 325.00
SPRINGBROOK SOFTWARE INC INFORMATION SYS SERVICE CONTRACT 2037 - 6030 225.00
Check Total: 2.000.00 AP- 00075006 MW
STONE, JEFF CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: 200.00 AP- 00075007 MW
STOP LOSS INSURANCE SERVICES SELF FUNDED INS EXCESS INSURANCE 3000 - 6744 27,322.70
Check Total: 27.322.70 AP- 00075008 MW
SUBSTITUTE PERSONNEL & ENGINEERING CONTRACT SERVICE 1029 - 4405 559.20
SUBSTITUTE PERSONNEL & INFORMATION SYS CONTRACT SERVICE 1037 - 4405 462.46
SUBSTITUTE PERSONNEL & CUSTOMER SERVICE CONTRACT SERVICE 1038 - 4405 994.45
SUBSTITUTE PERSONNEL & ENGINEERING CONTRACT SERVICE 2029 - 4405 559.20
SUBSTITUTE PERSONNEL & ENGINEERING - TWIN PEAKS BS BSTR, MIN PEAKS 2029 - 7070 - TPBSTR 1,058.21
SUBSTITUTE PERSONNEL & INFORMATION SYS CONTRACT SERVICE 2037 - 4405 462.46
SUBSTITUTE PERSONNEL & CUSTOMER SERVICE CONTRACT SERVICE 2038 - 4405 994.45
Check Total: 5.090.43 AP- 00075009 MW
SUTER WALLAUCH CORBETT &ASSOC DIO CONTRACT SERVICE 1027 - 4405 1,225.00
SUTER WALLAUCH CORBETT &ASSOC DIO CONTRACT SERVICE 2027 - 4405 1,225.00
User: THERESA
Report: OH_PMT_CLAIMS_BK Current Time: 17:26:24
Page: 10 Current Date: 02/02/2010
Vendor Name
TAHOE ASPHALT INC.
TAHOE ASPHALT INC.
TAHOE ASPHALT INC.
TAHOE BLUEPRINT
TAHOE BLUEPRINT
TAHOE BLUEPRINT
TAHOE MOUNTAIN NEWS
TAHOE MOUNTAIN NEWS
TAHOE PARADISE CHEVRON
TAHOE TRADING POST
TAHOE VALLEY ELECTRIC SUPPLY
TAMCO
TOPHEALTH
TOPHEALTH
TRPA
UUNE
UUNE
UNITED PARCEL SERVICE
UNITED PARCEL SERVICE
User: THERESA
Report: OH_PMT_CLAIMS_BK
Department / Proj Name
GEN & ADMIN - WTRLN,AL TAHOE
ENGINEERING - WTRLN,AL TAHOE
ENGINEERING - WTRLN, TATA
ENGINEERING - REPL GEN, LPPS
ENGINEERING - ANGORA TNK REPL
ENGINEERING - ECHO TANK REPL
DIO - PR EXP- EXTERNAL
DIO - PR EXP- EXTERNAL
UNDERGROUND REP
HEAVY MAINT
ELECTRICAL SHOP
GEN & ADMIN - WTRLN,AL TAHOE
ADMINISTRATION
ADMINISTRATION
ENGINEERING - ECHO TANK REPL
FINANCE
FINANCE
GEN & ADMIN
GEN & ADMIN
PAYMENT OF CLAIMS
Description
CONST RETAINAGE
WTLN, AL TAHOE
WTRLN, TATA LN
REPL GEN LPPS
TANK, ANGORA
TANK, ECHO
PUB RELATIONS
PUB RELATIONS
DIESEL
SHOP SUPPUES
PUMP STATIONS
CONST RETAINAGE
SUBSCRIPTIONS
SUBSCRIPTIONS
TANK, ECHO
OFFICE SUPPUES
OFFICE SUPPUES
POSTAGE EXPENSES
POSTAGE EXPENSES
Acct# / PrQj Code
Check Total:
2000 - 2605 - ATWL08
2029 - 8811 - ATWL08
2029 - 8866 - TATAWL
Check Total:
1029 - 8933 - RGLPPS
2029 - 7064 - ANGOTK
2029 - 8809 - ECHOTK
Check Total:
2001 - 4620
1004 - 6071
2003 - 6051
1027 - 6620 - PREEXT
2027 - 6620 - PREEXT
Check Total:
Check Total:
Check Total:
Check Total:
2000 - 2605 - ATWL08
Check Total:
1021 -4830
2021 - 4830
1039 -4820
2039 - 4820
1000 - 4810
2000 - 4810
Check Total:
2029 - 8809 - ECHOTK
Check Total:
Check Total:
Check Total:
Page: 11 Current Date: 02/02/2010
Current Time: 17:26:24
10,265.86
39,000.00
49,308.73
6,258.62
95.64
95.65
Amount Check Num bin
2,450.00 AP-00075010 MW
98,574.59 AP- 00074885
6 AP- 00075011
325.00
325.00
650.00 AP- 00075012
121.47
121.47 AP- 00075013
88.02
88.02 AP- 00075014
251.18
251.18 AP- 00075015
11,220.26
11,220.26 AP- 00074886
62.37
62.37
124.74 AP- 00075016
4,688.00
4,688.00 AP-00074887
44.80
44.80
89.60 AP- 00075017
500.00
500.00
1.000.00 AP- 00075018
MW
MW
MW
MW
MW
MW
MW
MW
MW
MW
MW
PAYMENT OF CLAIMS
Vendor Name Department / Proj Name Description Acct# / Proj Code Amount Check Num Iyp
UNIVERSAL HEALTH NETWORK SELF FUNDED INS PPO FEE 3000 - 6742 160.75
Check Total: 160.75 AP- 00075019 MW
USA BLUE BOOK PUMPS PUMP STATIONS 1002 - 6051 157.41
USA BLUE BOOK UNDERGROUND REP SMALL TOOLS 2001 - 6073 271.93
Check Total: 429.34 AP- 00075020 MW
VAN GILDER, JENNIFER CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: 200.00 AP- 00075021 MW
VERIZON CALIFORNIA DIAMOND VLY RNCH TELEPHONE 1028 - 6310 170.99
Check Total: 170.99 AP- 00075022 MW
WACKENHUT, NORMAN GEN & ADMIN UB SUSPENSE 1000 - 2002 112.19
WACKENHUT, NORMAN GEN & ADMIN UB SUSPENSE 2000 - 2002 112.20
Check Total: 224.39 AP- 00075023 MW
WATSON, CHERI CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE 2038 - 6660 - WCPROG 200.00
Check Total: 200.00 AP- 00075024 MW
WEDCO INC ELECTRICAL SHOP BUILDINGS 1003 - 6041 46.34
WEDCO INC ELECTRICAL SHOP PUMP STATIONS 1003 - 6051 108.81
WEDCO INC ELECTRICAL SHOP SHOP SUPPLIES 1003 - 6071 74.97
WEDCO INC ELECTRICAL SHOP BUILDINGS 2003 - 6041 2.31
Check Total: 432.43 AP- 00075025 MW
WEST PAYMENT CENTER ADMINISTRATION SUBSCRIPTIONS 1021 - 4830 220.28
WEST PAYMENT CENTER ADMINISTRATION SUBSCRIPTIONS 2021 -4830 220.27
Check Total: 440.55 AP- 00075026 MW
WESTERN ENERGETIX INC EQUIPMENT REP OIL & LUBE 1005 - 4630 449.22
WESTERN ENERGETIX INC EQUIPMENT REPAIR OIL & LUBE 2005 - 4630 449.22
Check Total: 898.44 AP- 00075027 MW
WESTERN NEVADA SUPPLY HEAVY MAINT SHOP SUPPLIES 1004 - 6071 101.14
WESTERN NEVADA SUPPLY GEN & ADMIN METERS,ETC INV 2000 - 0402 2,990.63
WESTERN NEVADA SUPPLY GEN & ADMIN VALVES INVENTORY 2000 - 0404 4,809.04
WESTERN NEVADA SUPPLY UNDERGROUND REP PIPE/CVRS /MHLS 2001 - 6052 1,288.56
WESTERN NEVADA SUPPLY HEAVY MAINTENANC BUILDINGS 2004 - 6041 207.71
WESTERN NEVADA SUPPLY CUSTOMER SERVICE SHOP SUPPLIES 2038 - 6071 870.00
User: THERESA
Report: OH_PMT_CLAIMS BK
Page: 12 Current Date: 02/02/2010
Current Time: 17:26:24
Vendor Name Department / Proj Name Description
WINZLER & KELLY CONSULT ENGRS ENGINEERING - EFFLUENT EVAL REP EXP PUMPS
ZERWECK, JOHN GEN & ADMIN - WTRLN,AL TAHOE CONST RETAINAGE
ZICKO, DAVID CUSTOMER SERVICE - WTR CONS PROG WTR CONS EXPENSE
User: THERESA
Report: OH_PMT_CLAIMS_BK
PAYMENT OF CLAIMS
t��: 811rA1M
Acct# / PrQj Code
Amount Check Num IXp.6
Check Total: 10.267.08 AP- 00075028 MW
1029 - 8676 - EFFLEV 3,001.00
Check Total: 3.001.00 AP- 00075029 MW
2000 - 2605 - ATWL08 60,615.81
Check Total: 60.615.81 AP- 00074888 MW
2038 - 6660 - WCPROG 200.00
Check Total: 200.00 AP- 00075030 MW
Grand Total: 808,149.29
dirand Total
SO7,214
Page: 13 Current Date: 02/02/2010
Current Time: 17:26:24
wis
Sourth Tahoe P.U.D. 01/18/10 VOID, TYPED & REVERSED AjP CHICK =MIE
NM, 37N 18, 2010, 9:14 PM - - -req: EC IEL E - - -1eg CL OL. - -loc: CNST---- joobb: 450349 #J380- -- pgn: EC200 <1.19>
Check Payee ID. Payee Bare Late Clack Atttai t
Type Subs Rel lb Ncte
AP00074489 V45024 APB /p RP
GRAND TOTALS:
Tbtal Void Machine Written
Tbtal Void Hand Written
Tbtal NbchirE Written
Tbtal Hand Written
Tbtal Reversals
Tbtal (welled
GRAND TOTAL
12/17/09
935.00 RV TR Reversed
0.00
0.00
0.00
fl/Vi 0.00
935.00
0.00
935.00
Nutter of Checks Processed:
Nutter of Checks Processed:
Number of Checks Processed.:
Nutter of Checks Processed:
Nutter of Checks Processed:
Nutter of Checks Processed:
1
1pL id: --
0
0
0
1
0
General Manager
Richard H. Solbrig
1 � - �� -� �'•r Directors
"- : y ,, o S o Jamey R. Jones
"!! ft Utility Pistrict
Dale Rise
Eric Schafer
1275 Meadow Crest Drive • South Lake Tahoe * CA 96150
Phone 530 544 -6474 • Fax 530 541-0614
BOARD AGENDA ITEM 14a
TO: Board of Directors
FROM: Richard Solbrig, General Manager,
MEETING DATE: February 4, 2010
ITEM — PROJECT: Conference with Legal Counsel — Anticipated Litigation (one case)
REQUESTED BOARD ACTION: Direct legal counsel.
DISCUSSION: Pursuant to Section 54956.9(b) of the California Government Code,
Closed Session may be held for conference with legal counsel regarding anticipation of
litigation.
SCHEDULE:
COSTS:
ACCOUNT NO:
BUDGETED AMOUNT REMAINING:
ATTACHMENTS:
CONCURRENCE WITH REQUESTED ACTION: CATEGORY: General
GENERAL MANAGER: YES NO
CHIEF FINANCIAL OFFICER: YES NO
-41-
General Manager
Richard H. Solbrig
!` ►L"" A • +.�,�t: =r , t # Directors
0 o [(Vrrr�
��,,,h � �� Chris Cefalu
� James R. Jones
µ �-- Ut ,` Eric Schafer
1275 Meadow Cry Chore • South Lake Tahoe • CA 96150
Phone 530 544 -6474 • Fax 530 541 -0614
BOARD AGENDA ITEM 14b
TO: Board of Directors
FROM: Richard H. Solbrig, General Manager
MEETING DATE: February 4, 2010
ITEM — PROJECT: Conference with Legal Counsel — Existing Litigation
REQUESTED BOARD ACTION: Direct staff.
DISCUSSION: Pursuant to Section 54956.9(a) of the California Govemment Code,
Closed Session may be held for conference with legal counsel regarding existing
litigation: Meyers Landfill Site - United States of America vs. El Dorado County and City
of South Lake Tahoe and Third Party Defendants, Civil Action No. S -01 -1520 LKK
GGH, United States District Court for the Eastern District of Califomia.
SCHEDULE:
COSTS:
ACCOUNT NO:
BUDGETED AMOUNT REMAINING:
ATTACHMENTS:
CONCURRENCE WITH REQUESTED ACTION: CATEGORY: Sewer
GENERAL MANAGER: YES NO
CHIEF FINANCIAL OFFICER: YES NO
-43-