TK594-593South Tahoe Public Utility District
Inspection report
Date :Work Order :Pipe Segment Ref. :Weather :Surveyed By :Certificate Number :
Year laid :Pre-cleaning :Pipe Joint Length :Direction :Total Length :Length Surveyed :
WinCanVX Legacy Data // Page: 1
City :SLT Drainage Area :K28 Upstream MH :TK594
Street :JULIE Media Label :TAHOE KEYS Up Rim to Invert :0.0
Location Code :Light highway Flow Control :Not Controlled Downstream MH :TK593
Location Details :Sheet Number :Down Rim to Invert :6.6
Pipe shape:Circular Sewer Use:
Pipe size:6 Sewer Category :SEC
Pipe material:Asbestos Cement Purpose:Routine Assessment
Lining Method :Owner :
Additional Info :
1:1761 Distance Code Observation Counter Photo Grade
0.00 AMH Manhole / TK593 00:00:00
0.00 MWL Water Level 00:00:00
15.70 JOM Joint Offset Medium / JOINT OFFSET SMALL 00:00:04 S1
29.30 B Broken, at 08 o'clock / THERE IS A SMALL PEASE OF
BROKEN PIPE AT THE JOINT
00:00:12 S3
41.80 TF Tap Factory Made, at 08 o'clock, 4 inch dim 00:00:18
62.80 TF Tap Factory Made, at 03 o'clock, 4 inch dim 00:00:20
83.70 TF Tap Factory Made, at 08 o'clock, 4 inch dim 00:00:26
84.80 TF Tap Factory Made, at 03 o'clock, 4 inch dim 00:00:28
150.70 TF Tap Factory Made, at 08 o'clock, 4 inch dim 00:00:37
152.40 TF Tap Factory Made, at 03 o'clock, 4 inch dim 00:00:39
166.90 TF Tap Factory Made, at 07 o'clock, 4 inch dim 00:00:43
168.70 TF Tap Factory Made, at 03 o'clock, 4 inch dim 00:00:44
170.50 MWL Water Level 00:00:45
179.20 MWL Water Level 00:00:46
233.30 AMH Manhole / TK594 00:00:51
11/14/2008 336391 Dry Francisco Avina U-508-6922 TK594-593
Jetting 0.0Upstream 233.3 233.3
QSR QMR SPR MPR OPR SPRI MPRI OPRI
3111 0000 4.0 0.0 2.0 0.0 2.04.0
TK593
South Tahoe Public Utility District
Page 2
Section Pictures - 11/14/2008 - TK594-593
SLT JULIE 11/14/2008 TK594-593 412
, 00:00:04, 15.70
Joint Offset Medium / JOINT OFFSET SMALL
, 00:00:12, 29.30
Broken, at 08 o'clock / THERE IS A SMALL PEASE OF
BROKEN PIPE AT THE JOINT
City Street Date Pipe Segment Reference Nr.