Loading...
TK759-668South Tahoe Public Utility District Inspection report Date :Work Order :Pipe Segment Ref. :Weather :Surveyed By :Certificate Number : Year laid :Pre-cleaning :Pipe Joint Length :Direction :Total Length :Length Surveyed : WinCanVX Legacy Data // Page: 1 City :SLT Drainage Area :K-29 Upstream MH :TK759 Street :SHOT ST Media Label :TAHOE KEYS Up Rim to Invert :0.0 Location Code :Light highway Flow Control :Not Controlled Downstream MH :TK668 Location Details :Sheet Number :Down Rim to Invert :0.0 Pipe shape:Circular Sewer Use: Pipe size:6 Sewer Category :SEC Pipe material:Vitrified Clay Pipe Purpose:Routine Assessment Lining Method :Owner : Additional Info : 1:2717 Distance Code Observation Counter Photo Grade 0.00 AMH Manhole / TK759 00:00:00 0.00 MWL Water Level 00:00:01 28.50 TB Tap Break-In, at 03 o'clock, 4 inch dim 00:00:06 63.50 TF Tap Factory Made, at 09 o'clock, 4 inch dim 00:00:11 65.60 TF Tap Factory Made, at 03 o'clock, 4 inch dim 00:00:11 174.70 DSF Deposits Settled Fine, from 05 to 07 o'clock 00:00:26 M2 178.90 DSF Deposits Settled Fine, from 05 to 07 o'clock 00:00:26 M2 6/3/2009 26481 Dry Jason Chatham U-1207-6103 TK759-668 Not Known 0.0Downstream 360.0 185.5 QSR QMR SPR MPR OPR SPRI MPRI OPRI 0000 2200 0.0 4.0 0.0 2.0 2.04.0 TK759 TK668 South Tahoe Public Utility District Inspection report Date :Work Order :Pipe Segment Ref. :Weather :Surveyed By :Certificate Number : Year laid :Pre-cleaning :Pipe Joint Length :Direction :Total Length :Length Surveyed : WinCanVX Legacy Data // Page: 2 City :SLT Drainage Area :K-29 Upstream MH :TK759 Street :SHOT ST Media Label :TK Up Rim to Invert :0.0 Location Code :Light highway Flow Control :Not Controlled Downstream MH :TK668 Location Details :Sheet Number :Down Rim to Invert :0.0 Pipe shape:Circular Sewer Use: Pipe size:6 Sewer Category :SEC Pipe material:Vitrified Clay Pipe Purpose:Maintenance Related Lining Method :Owner : Additional Info : 1:2717 Distance Code Observation Counter Photo Grade 0.00 AMH Manhole / TK759 00:00:00 0.00 MWL Water Level 00:00:00 28.30 TB Tap Break-In, at 02 o'clock, 4 inch dim 00:00:24 64.10 TF Tap Factory Made, at 10 o'clock, 4 inch dim 00:00:27 66.20 TF Tap Factory Made, at 02 o'clock, 4 inch dim 00:00:28 354.40 MLC Lining Change / LINER 00:00:54 356.10 ATC Tee Connection, at 06 o'clock, 6 inch vertical / DROP 00:00:57 7/7/2016 01 Dry IV U-213-13107 TK759-668 Not Known 0.0Downstream 360.0 356.1 QSR QMR SPR MPR OPR SPRI MPRI OPRI 0000 0000 0.0 0.0 0.0 0.0 0.00.0 TK759 TK668