TK761-TK760South Tahoe Public Utility District Inspection report Date :Work Order :Pipe Segment Ref. :Weather :Surveyed By :Certificate Number : Year laid :Pre-cleaning :Pipe Joint Length :Direction :Total Length :Length Surveyed : WinCanVX Master Server // Page: 1 City :SLT Drainage Area :K-29 Upstream MH :TK761 Street :Shop St Media Label :Up Rim to Invert :0.0 Location Code :Flow Control :Downstream MH :TK760 Location Details :Sheet Number :Down Rim to Invert :0.0 Pipe shape:Circular Sewer Use: Pipe size:6 Sewer Category :SEC Pipe material:Vitrified Clay Pipe Purpose: Lining Method :Owner : Additional Info : 1:2246 Distance Code Observation Counter Photo Grade 0.00 AMH Manhole / TK761 00:00:00 0.00 MWL Water Level, 5% of cross sectional area 00:00:00 14.20 JSM Joint Separated Medium / Dirt at Joints S1 79.50 VZ Vermin Other, quantity:, 1 M1 182.50 TFD Tap Factory Made Defective at 9 o'clock, 4inch dim / Roots M2 182.50 RMC Roots Medium Connection from 8 o'clock to 10 o'clock, 15% lost M3 184.10 RFJ Roots Fine Joint from 12 o'clock to 12 o'clock, within 8 inch M1 184.60 TFD Tap Factory Made Defective at 3 o'clock, 4inch dim / Roots M2 291.30 MWM Water Mark, 50% of cross sectional area M4 297.50 AMH Manhole / TK760 6/5/2018 JASON CHATHAM U-1207-6103 TK761-TK760 Jetting Downstream 297.5 297.5 QSR QMR SPR MPR OPR SPRI MPRI OPRI 1100 4131 1.0 13.0 1.0 2.2 2.014.0 TK761 South Tahoe Public Utility District Page 2 Section Pictures - 6/5/2018 - TK761-TK760 SLT Shop St 6/5/2018 TK761-TK760 218 , 00:00:00, 0.00 Water Level, 5% of cross sectional area , , 79.50 Vermin Other, quantity:, 1 , , 14.20 Joint Separated Medium / Dirt at Joints , , 182.50 Tap Factory Made Defective at 9 o'clock, 4inch dim / Roots City Street Date Pipe Segment Reference Nr. South Tahoe Public Utility District Page 3 Section Pictures - 6/5/2018 - TK761-TK760 SLT Shop St 6/5/2018 TK761-TK760 218 , , 182.50 Roots Medium Connection from 8 o'clock to 10 o'clock, 15% lost , , 184.60 Tap Factory Made Defective at 3 o'clock, 4inch dim / Roots , , 184.10 Roots Fine Joint from 12 o'clock to 12 o'clock, within 8 inch , , 291.30 Water Mark, 50% of cross sectional area City Street Date Pipe Segment Reference Nr. South Tahoe Public Utility District Page 4 ScanExplorer Overview - 6/5/2018 - TK761-TK760 SLT Shop St 6/5/2018 TK761-TK760 _24 City Street Date Pipe Segment Reference South Tahoe Public Utility District Page 5 ScanExplorer Overview - 6/5/2018 - TK761-TK760 SLT Shop St 6/5/2018 TK761-TK760 _24 City Street Date Pipe Segment Reference Legend Distance PACP Code Observation (1)0.00 AMH Manhole (2)0.00 MWL Water Level, 5% of cross sectional area (3)14.20 JSM Joint Separated Medium (4)79.50 VZ Vermin Other, quantity:, 1 (5)182.50 TFD Tap Factory Made Defective at 9 o'clock, 4inch dim (6)182.50 RMC Roots Medium Connection from 8 o'clock to 10 o'clock, 15% lost (7)184.10 RFJ Roots Fine Joint from 12 o'clock to 12 o'clock, within 8 inch (8)184.60 TFD Tap Factory Made Defective at 3 o'clock, 4inch dim (9)291.30 MWM Water Mark, 50% of cross sectional area (10)297.50 AMH Manhole