Loading...
Board 2 Jan 2020 Staff Report_So Y FS_final_2 Page Handouts1/2/2020 1 SOUTH TAHOE PUBLIC UTILITY DISTRICT Regular Board Meeting Board Agenda Item 11.b. South Y Feasibility Study January 2, 2020 I. Bergsohn, PG, HG Remedial Alternatives 2019 Regional Plume Characterization (LRWQCB) Questions – Open Forum South Y Feasibility Study 1/2/2020 2 FEASIBILITY STUDY Screen Modeled Alternatives for Engineering Evaluation (6 Alternatives) 1) Define Infrastructure Needs 2) Develop Life Cycle Cost Estimates 3) Complete Initial Study Checklists/Cost of Mitigation (3 Alternatives) Select and Develop Recommended Alternative (1 Alternative) ALTERNATIVE OPERATIONS PCE TREATMENT EMERGENCY WATER SUPPLY 1 - Base TKWC and LBWC PWS Wells to meet average annual demands (2009 -2018). Maintain current levels of VOC Treatment (TKWC 2). Operate LBWC 5 as lag well (starting in 2021). STPUD 2 - Targeted Pumping Maximize PCE mass removal. TKWC and LBWC PWS Wells to meet average annual demands (2009 -2018). Increase VOC Treatment. Operate LBWC 5 as lead well (starting in 2021). Install new Replacement Well and Groundwater Treatment System to meet Drinking Water Standards. STPUD 3 – Source Conversion from Groundwater to Surface Water Over next 15 years – Attain permits, negotiate agreements and complete design/construction and testing of a new surface water treatment plant to meet 4.4 MGD MDD for TKWC and LBWC water systems. TKWC and LBWC PWS Wells to meet average annual demands (2009 -2018). Over Next 15 years- Maintain current levels of VOC Treatment (TKWC 2). Operate LBWC 5 as lag well (starting in 2021). STPUD REMEDIAL ALTERNATIVES 1/2/2020 3 Alternatives Evaluation – Summary of Costs (Jan 2020) Alt 1. Base Alt 2: Targeted Pumping (revised September 2019)Alt. 3: Conversion to Surface Water Option 1: Potable Re-use Option 2: To Waste (STPUD) Option 3: To Waste (STPUD;CSLT) Capital $0 (no change)$5.1M $3.1 M $3.2 M $57.6 M O&M (20 Years) $0 (no change)$6.0 M $17.0 M $10.4 M $7.9 M (15 Years) Total NPV (2019$s)$0 $11.1 M 20.1 M $13.6 M $65.5 M Time to Implement (years) Current 3- 7 (planning, permitting, design/engineering, construction and testing) 10 – 15 (planning, permitting, design/engineering, construction and testing) Alt. 1: Base Alt 2: Targeted Pumping (revised September 2019)Alt. 3: Conversion to Surface Water Option 1: Potable Re-use Option 2: To Waste (STPUD) Option 3: To Waste (STPUD;CSLT) PCE Removed over 20 years Lbs.278 - 1760 773- 3293 773- 3293 232 – 1418 (15 years) Clean-Up Time PCE < 4 µg/L 27 yrs. 18 yrs. 18 yrs.> 15 yrs. (Total Capital + O&M)/Water Produced $/MG 0 $1,695 $5,599 $3,805 $23,176 Alternatives Evaluation- PCE Removal 1/2/2020 4 Ownership Long-Term O&M Excess Water/ Purchase Water Agreement Alternative 2, Option 1 2019 Regional Plume Characterization Objectives Estimate lateral and vertical extent of PCE contamination Identify contaminant pathways Provide detailed 3-d “snapshot” view of Plume 1/2/2020 5